Limited Warranty WARNING Digital Security Controls Ltd. warrants the original purchaser that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use. During the warranty period, Digital Security Controls Ltd. shall, at its option, repair or replace any defective product upon return of the product to its factory, at no charge for labour and materials.
Ta ble of Contents Section 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1.1 PC4820 Access Control Module Specifications....................................................................................1 Section 2: Installation and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2.1 Plan Your Installation.........................................................................
PC4820 Access Control Module W DO NOT connect transformer to receptacle controlled by a switch. SECONDARY 16.5VAC, 40VA PRIMARY 50Hz or 60Hz Transformer: 16.
Section 1: Intro duction The PC4820 is a versatile Dual Card Reader Access Control module which will enable you to meet the most demanding access control requirements of an installation. The PC4820 is monitored and programmed via the PC4010/4020 control panel. Up to 16 PC4820 modules can be connected to a PC4010/4020 via a 4-conductor Combus, using standard, unshielded station wire. Each PC4820 is capable of providing supervision for two door inputs which may to assigned to any PC4010/4020 zone.
Section 2: Installation and Wiring 2.1 Plan Your Installation When designing a security system with access control it is best to first lay out the system on paper. This will help determine the total number of zones, additional expanders, access control points and other system components that will be required to complete the installation. When the locations of all points of access are known, appropriate points may be chosen for access control.
The PC4010/4020 will send an Auto-arm Abort reporting code to the monitoring station if the reporting code is programmed. The Auto-arm will restart at the end of the Postpone Arm time (ref # [00020305]) unless the partition has been manually rearmed. The auto-arm may be postponed as many times as desired. NOTE: To postpone an auto-arm, the user must be assigned to the partition(s) being armed, and the user’s access card must have the disarm attribute enabled.
Reader LED Flash Rates Most access card readers will have an LED output to provide visual feedback when the access card is presented to the reader.
PC4820 Access Control Module Reader Connections Polaris Readers (POL-1, POL-2, POL-2KP) ShadowProx Readers NOTE: Only use the +5V power supply when using Polaris Readers. NOTE: Only use the +12V power supply when using ShadowProx Readers.
Section 3: Programming the PC4820 Programming of the PC4820 is performed at the PC4010/ 4020 control panel in Installer’s Programming mode. Refer to Section 4 “How to Program” of the PC4010/4020 Installation Manual for instructions. The following programming sections must be programmed for each PC4820 enrolled on the system. To select a module, enter reference number [0011XX] where “XX” refers to the PC4820 module number.
NOTE*: The Door Shunt and Unlock Safety features are only available when the PC4820 is connected to a PC4020 v3.2 or higher. • Unlock on Fire: If enabled, when a fire alarm occurs on the same partition as the PC4820 door, the door will unlock. The door will lock again when a successful fire reset is performed. NOTE: This feature is only available on PC4020 v3.5 or higher. 3.
However, if the partition is disarmed while the door unlock schedule is active, the door will unlock, and will remain unlocked until the scheduled end time. NOTE: If the door is assigned to more than one partition, the door will only lock once the last partition to be armed has begun its exit delay. The default date schedule is 00 (disabled). Request To Exit (REX) Schedule Ref # [0011XX01YY07] where XX = module #, YY = door # This schedule controls the Unlock on REX option.
3.7 Access Level Ref # [0011XX01YY10] where XX = module #, YY = door # Access levels allow specific users to have access to areas of the system at various times of the day. Each door can have multiple access levels assigned to it. Each access level will follow one date schedule. There are 63 access levels for each door. To program access levels, select an access level number (02-63) and then enter the schedule number that the access level will follow.
Section 4: Diagnostics 4.1 Hardware Reset On occasion, it may be necessary to perform a reset of the PC4820 to factory default programming. To perform a hardware reset of the PC4820, the following steps must be performed: 1. Power down the PC4010/4020 by removing both AC and battery power from the control panel. 2. Power down the PC4820 modules by removing both AC and battery power from the units. 3.
Section 5: PC4820 Programming Worksheet Record your PC4820 module programming information here. Make one copy of this sheet for each PC4820 you will install. [0011] PC4820 Options (XX = module #; YY = door#) [0011XX] PC4820 Module Number: |______|______| 00 |______|______| [0011XX00] Reader Type Default: [0011XX01YY] Door 01 Select Door Number: [0011XX01YY00] NOTE: *The Door Shunt and Unlock Safety features are only available when the PC4820 is connected to a PC4020 v3.2 or higher.
FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use this equipment. This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception.