Installation guide
PC1404 
28
Zone Follower PGM requires 2 programming sections for attributes: the normal PGM attribute Sections [501-514] and Sections [551-
564] for zone assignment.
[551]-[564] PGM Zone Assignment
27 Police Code
28 For Future Use
29 Zone Follower
30 Status Alarm Memory
Notes: 
A change of default setting will NOT affect the output.
A change of default setting will affect the output.
Attribute: 
123 4 56 7 8
ON
OFF
Service Req. 
Event 
AC Fail TLM Fault FTC Enabled Device Fault Device 
Tamper
Device Low 
Battery
Loss of 
Clock 
Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled
09 System Trouble
   
Attribute: 
123 4 56 7 8
ON
OFF
Burglary 
Event 
Fire 
Event
Panic Event Medical 
Event
Supervisory 
Event
Priority 
Event
Duress Event Output 
Follows 
Timer 
Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled
10 System Event
  
Note: 
If a System Event PGM is programmed to follow the Command Output Timer, attribute 8 must be enabled.
Location PGM 29 Zone Follower
Option On Option Off
Option 1 For Future Use
Option 2 For Future Use
Option 3 True Output Inverted
Option 4 For Future Use
Option 5 For Future Use
Option 6 For Future Use
Option 7 For Future Use
Option 8 AND Logic Or Logic
Section Number Output Number Zone Follower Zone
Main Board 1 2 3 4 5 6 7 8
[551] PGM 1
[552] PGM 2
PC5208
[553] PGM 3
[554] PGM 4
[555] PGM 5
[556] PGM 6
[557] PGM 7
[558] PGM 8
[559] PGM 9
[560] PGM 10
12 3 4 5 6 78
PGM 
Option
 =ON
 OFF
Not Used 
–
Not Used 
–
True Output 
Inverted
Follows Timer 
ON/OFF
Code Req. 
No Code
Not Used 
No
Not Used 
No
Not Used 
No