Specifications
31
P R O G R A M M I N G W O R K S H E E T S
[009] PGM Output Programming (PGM 1 and 2)
(Section 5.11 “PGM Output Options”)
Programmable Output Options
01 Burglary and Fire Bell Output 13 Kissoff Output
02 For future use 14 Ground Start Pulse
03 Sensor Reset 15 Remote Operation (DLS-1 Support)
04 2-wire Smoke Support (PGM2 only) 16 LINKS 1000 Support (PGM1 only)
05 System Armed Status 17 Away Armed Status
06 Ready To Arm 18 Stay Armed Status
07 Keypad Buzzer Follow Mode 19 Command Output #1 ([✱] [7] [1])
08 Courtesy Pulse 20 Command Output #2 ([✱] [7] [2])
09 System Trouble Output (with Trouble options) 21 For future use
10 Latched System Event [Strobe (with Event options)] 22 For future use
11 System Tamper (all sources: zones, kpd, modules) 23 Silent 24 Hour (PGM2 Only)
12 TLM and Alarm 24 Audible 24 Hour (PGM2 Only)
Output types [03], [04] and [20] cannot be used together on the same system.
Default
19
I_______I_______I PGM 1
10
I_______I_______I PGM 2
Program PGM Option Attributes in sections [141] & [142].
[012] Keypad Lockout Options
(Section 5.21 “Keypad Lockout Options”)
If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
I_______I_ ______I_______I Number of Invalid Codes Before Lockout (001-255 codes)
000
I_______I_ ______I_______I Lockout Duration (001-255 minutes)
[013] First System Option Code
Default Option ON OFF Section
OFF
I________I 1 Normally Closed Loops End-of-Line Resistors 2.8
OFF
I________I 2 Double End-of-Line Resistors Single End-of-Line Resistors 2.8
ON
I________I 3* Panel shows all troubles when armed Panel shows only Fire troubles when armed 3.4
OFF
I________I 4 Tampers/Faults do not show as open Tampers/Faults show as open 5.8
OFF
I________I 5 Zone 1 is Fast Loop Response Zone 1 is Standard Loop Response 5.24
ON
I________I 6 Audible Exit Fault Enabled Audible Exit Fault Disabled 5.18
ON
I________I 7
Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown 5.20
OFF I________I 8 Temporal Three Fire Signal Enabled Standard Pulsed Fire Signal 5.13
* Option 3 must be OFF if LCD keypads older than v2.0 are used.
[014] Second System Option Code
Default Option ON OFF Section
OFF
I________I 1 Arm / Disarm Bell Squawk enabled Arm / Disarm Bell Squawk disabled 5.17
OFF
I________I 2 Bell Squawk During Auto Arm No Bell Squawk During Auto Arm 5.18
OFF
I________I 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay 5.18
OFF
I________I 4 Bell Squawk On Entry Delay No Bell Squawk On Entry Delay 5.18
OFF
I________I 5 Bell Squawk On Trouble No Bell Squawk On Trouble 3.4
ON
I________I 6 Audible Exit with Urgency Silent Exit Delay 5.18
OFF
I________I 7 Exit Delay Termination Enabled Exit Delay Termination Disabled 5.18
OFF
I________I 8 Fire Bell is Continuous Fire Bell follows Bell Cut-off 5.13