Specifications
30
P R O G R A M M I N G W O R K S H E E T S
Basic Programming
Zone Definitions
00 Null Zone (Not Used) 09 24 Hour Supervisory (LINKS) 18 24 Hour Sprinkler
01 Delay 1 10 24 Hour Supervisory Buzzer 19 24 Hour Water
02 Delay 2 11 24 Hour Burglary 20 24 Hour Freeze
03 Instant 12 24 Hour Holdup 21 24 Hour Latching Tamper
04 Interior 13 24 Hour Gas 22 Momentary Keyswitch Arm
05 Interior, Stay/Away 14 24 Hour Heat 23 Maintained Keyswitch Arm
06 Delay, Stay/Away 15 24 Hour Medical 24 LINKS Answer
07
Delayed 24 Hour Fire (Hardwired)
16 24 Hour Panic 87 Delay 24 Hour Fire (Wireless)
08
Standard 24 Hour Fire (Hardwired)
17 24 Hour Emergency 88 Standard 24 Hour Fire (Wireless)
If 24-hour Buzzer zones are used, keypads must be installed
[001] Zone 1-8 Definitions
(Section 5.2 “Zone Programming”)
Default Default
01
I_______I_______I Zone 1 04 I_______I_______I Zone 5
03
I_______I_______I Zone 2 04 I_______I_______I Zone 6
03
I_______I_______I Zone 3 00 I_______I_______I Zone 7
03
I_______I_______I Zone 4 00 I_______I_______I Zone 8
Keypad zones are assigned in Section [020]. Zone Attributes are assigned in Sections [101] - [108].
Zone assignment is in section [202].
[005] System Times
Default [001-255]
030
I_______I_ ______I_______I Entry Delay 1 (in seconds) (Section 5.18 “Entry/Exit Delay Options”)
045 I_______I_______I_______I Entry Delay 2 (in seconds) (Section 5.18 “Entry/Exit Delay Options”)
120 I_______I_______I_______I Exit Delay (in seconds) (Section 5.18 “Entry/Exit Delay Options”)
004 I_______I_______I_______I Bell Cut-off (in minutes) (Section 5.13 “Siren”)
[006] Installer’s Code
(Section 4.1 “Installer Programming”)
Default
1555
I_______I_______I_______I_______I
[007] Master Code
(Section 5.1 “Programming Security Codes”)
Default
1234
I_______I_______I_______I_______I
[008] Maintenance Code
(Section 5.1 “Programming Security Codes”)
Default
AAAA
I_______I_______I_______I_______I