Specifications

P R O G R A M D E S C R I P T I O N S
18
Zone Restoral
If the Restoral on Bell Time-out option is selected, the panel
will send the Zone Restoral Reporting Code for the zone if the
bell cut-off time has expired
and
the zone is secured. If the zone
is not secured when the alarm output times out, the panel will
send the restoral immediately once the zone is secured, or the
system is disarmed.
If the Restoral on Bell Time-out option is not selected, the
panel will immediately send the Zone Restoral Reporting Code
when the zone is secured, regardless of whether or not the
alarm output is active.
24 Hour type zones will report the restoral
immediately once the zone is secured.
Zone Restoral Reporting Codes .......................Section [324]
Restoral on Bell Time-out ........................... Section [380]: [2]
Closings (Arming Codes)
The panel will transmit a Closing Reporting Code to indicate that
the system is armed. A different reporting code can be transmitted
for each general access code and master/supervisory code to
identify who has armed the system.
A Special Closing reporting code will be transmitted if the
system is armed using any of the following methods:
Quick Arming
Arming via keyswitch
Auto Arm
Arming using the Away function key
Arming with the Maintenance Code
Arming using the Stay function key
Arming via the DLS Software
If programmed, a Partial Closing Reporting Code will be sent
along with the closing reporting code if one or more zones were
manually bypassed when the system was armed to warn the
monitoring station of a security compromise.
A Closing by Duress reporting code will be sent along with a
duress reporting code if the system is armed using a duress
code. The duress transmission is sent as soon as the code is
entered.
If the Closing Confirmation option is enabled, once the exit
delay expires, the keypad will sound a series of eight beeps to
confirm to the user that the closing code was sent and received
by the central station.
Closing (Arming) Reporting Codes ........ Section [339]-[342]
Special Closing Reporting Code ...................... Section [343]
Partial Closing Reporting Code ........................ Section [343]
Closing by Duress Reporting Codes................ Section [343]
Closing by Master/Supervisor Codes...............Section [343]
Closing Confirmation.................................. Section [381]: [4]
Openings (Disarming Codes)
The panel will transmit an Opening Reporting Code to indicate
that the system has been disarmed. A different reporting code
can be transmitted for each general access code and the
master/supervisory code to identify who has disarmed the
system.
A Special Opening reporting code will be transmitted if the
system is disarmed using any of the following methods:
Disarming using the maintenance code
Disarming via the DLS software
Disarming via keyswitch
If an alarm occurred while the system was armed, an Opening
After Alarm
reporting code will be sent along with an opening
reporting code when the user disarms the system.
An Opening by Duress reporting code will be transmitted in
addition to the duress reporting code if the system is disarmed
using a Duress code.
Opening (Disarming) Reporting Codes . Section [344]-[347]
Special Opening Reporting Code .................... Section [348]
Opening by Duress Reporting Codes .............. Section [348]
Opening by Master/Supervisor Codes ............. Section [348]
Opening After Alarm .........................................Section [328]
Tampers
If the panel is programmed for Double EOL zones (see Section
2.8 – “Zone Wiring”), the panel will report a Zone Tamper Alarm
reporting code if an open condition is present. A different
reporting code can be programmed to identify each zone. The
Zone Tamper Restoral reporting code will be transmitted
immediately when the tamper condition is restored.
A General System Tamper Reporting Code will be transmitted
when the tamper zone on any module is violated. The General
System Tamper Restoral Reporting Code will be transmitted
when the tamper zone on all modules are restored.
By enabling Tampers/Faults Do Not Show as Open, Faults
and Tampers will not show as open on the keypad, and will be
hidden from the end user. If the option is disabled, Faults and
Tampers will show as open.
Entering and exiting Installer’s Programming will
not reset the system tampers. All tamper
conditions must be physically restored.
Tamper Reporting Codes.................................. Section [330]
Tamper Restoral Reporting Codes ................... Section [334]
General System Tamper and Restoral.............. Section [338]
Tampers/Faults Do Not Show Open ............. Section [013]: 4
Priority/Emergency
The panel will transmit a Keypad Fire Alarm Reporting Code
and
the Keypad Fire Restoral Reporting Code when the Fire
Keys on any keypad are pressed for two seconds.
The panel will transmit a Keypad Auxiliary Alarm Reporting
Code
and
the Keypad Auxiliary Restoral Reporting Code when
the Auxiliary Keys on any keypad are pressed for two seconds.
The panel will transmit a Keypad Panic Alarm Reporting Code
and
the Keypad Panic Restoral Reporting Code when the Panic
Keys on any keypad are pressed for two seconds.
The panel will transmit a Duress Reporting Code any time the
Duress code is entered at any keypad.
If PGM2 is being used for 2-wire smoke detectors or 24 hour
operation, the panel will send a PGM2 Alarm reporting code if
the zone goes into alarm. The panel will transmit the PGM2
Restoral reporting code when the zone is restored (see Section
5.11 “PGM Output Options”).
Priority Alarm and Restoral Reporting Codes ..Section [329]
Duress Alarm.....................................................Section [328]