Specifications

1
1.1 Specifications
Downloading Software Support
PC1555 uses DLS-1 v6.3 and up
Flexible Zone Configuration
Six fully programmable zones; system expandable to eight
zones using keypad zone inputs and wireless zones
38 access codes: one master code, one maintenance code,
two duress codes, two supervision codes and 32 general
access codes
27 zone types; 8 programmable zone attributes
Normally closed, single EOL and double EOL zone wiring
• Eight wireless zones available using the PC5132 Wireless
Receiver
Audible Alarm Output
Supervised Bell Output (current limited at 3 amps), 12V
DC
Steady or Pulsed Output
EEPROM Memory
Does not lose programming or system status on complete AC
and Battery failure
Programmable Outputs
One programmable voltage output and one programmable
voltage output/input; 21 programmable options
PGM1 = 50mA; PGM2 = 300mA
Powerful 1.5 Amp Regulated Power Supply
550 mA Auxiliary Supply, 12 V
DC
Positive Temperature Coefficient (PTC) components replace
fuses
Supervision for loss of AC power, low battery
Internal clock locked to AC power frequency
Power Requirements
Transformer = 16.5 V
AC, 40VA
Battery = 12 volt 4 Ah minimum rechargeable sealed lead
acid battery
Remote Keypad Specifications
Three keypads available:
- PC1555RKZ eight zone LED keypad with zone input
- PC5508Z eight zone LED keypad with zone input
- LCD5500Z Alphanumeric keypad with zone input
All keypads have five programmable function keys
Connect up to eight keypads
4-wire (Quad) connection to Keybus
Built in piezoelectric buzzer
Digital Communicator Specifications
• Supports major communication formats including SIA and
Contact ID
Event-initiated personal paging
Three programmable telephone numbers
Two account numbers
Supports LINKS1000 cellular communication
Supports LINKS2X50 Long Range Radio Transmitter
DTMF and pulse dialing
DPDT line seizure
Anti-jam feature
Split reporting of selected transmissions to each telephone
number
System Supervision Features
The PC1555 continuously monitors a number of possible trouble
conditions including:
AC power failure
Trouble by zone
Tamper by zone
Fire trouble
Telephone line trouble
Failure to communicate
Low battery condition
Bell output trouble
Module fault (supervisory or loss of internal clock)
AUX Power Supply Trouble
False Alarm Prevention Features
Audible Exit Delay
Audible Exit Fault
Communication Delay
Urgency on Entry Delay
Quick Exit
Additional Features
Auto Arm at specified time
Keypad-activated alarm output and communicator test
All modules connect to the system via a four wire Keybus up
to 1000’/330m from main panel
An event buffer which records the past 128 events with both
the time and date at which they occurred; buffer can be
printed using PC5400 serial interface module, or viewed with
the LCD5500Z keypad.
• Supports the addition of the PC5132 Wireless receiver for
integration of wireless devices
Uploading and downloading capability
Local downloading capability through the use of the PC-LINK
adaptor
Added Keybus fault protection: clock and data outputs have
been programmed to withstand shorts to +12v to prevent
control panel damage