User manual
6
8. Time & Date Programming and Temperature Display
Press [][6] then enter your master access code to enter User
Functions. Use the [<][>] buttons to find the menu option, then
press [
] to select. Enter the time in 24-hr. format (HH:MM), fol-
lowed by the date (MM:DD:YY).
Press [#] to exit programming. If you are viewing a “Loss of Clock” trouble from within the trouble
menu ([
][2]), press [] to directly enter Date and Time programming (see Trouble Conditions).
NOTE: Your installer may have programmed your system to display the time and date while the
keypad is idle. Press the [#] button to temporarily clear the date and time display if desired.
NOTE: The SCW9055/9057 clock display can be automatically programmed if a 3G
Communicator is connected. This feature must be enabled by your installer.
The SCW9055/9057 system and WT5500 keypad can also display the outdoor temperature (Faren-
heit or Celsius) from the 2-way outdoor siren. This feature must be enabled by your installer.
9. Bypassing Zones
Use the zone bypassing feature when you need access to a protected area while the system is
armed, or when a zone is temporarily out of service but you need to arm the system. Bypassed
zones will not be able to sound an alarm. As a result, bypassing zones reduces the level of security.
If you are bypassing a zone because it is not working, call a service technician immediately so that
the problem can be resolved and your system returned to proper working order. Ensure that no
zones are unintentionally bypassed when arming your system. Zones cannot be bypassed once the
system is armed. Bypassed zones (except for 24-hr zones) are automatically cancelled each time the
system is disarmed and must be bypassed again, if required, before the next arming.
With the system disarmed:
Activating All Bypassed Zones
To remove bypass (all zones):
1. Press [
][1], then your access code.
2. Press [0][0].
3. To exit bypassing mode and return to the Ready state, press [#].
Recalling Bypassed Zones
To recall the last set of bypassed zones:
1. Press [
][1], then your access code.
2. Press [9][9].
3. To exit bypassing mode and return to the Ready state, press [#].
9.1 Bypass Group
A Bypass Group is a selection of zones programmed into the system. If you bypass a group of zones
on a regular basis, you can program them into a Bypass Group, so that you do not have to bypass
each zone individually. Note that only one Bypass Group can be programmed at a time.
To program a Bypass Group:
1. Press [
][1], then enter your access code.
2. Enter the 2-digit numbers (01-34) of the zones to be included in the Bypass Group or use the
[<][>] buttons to find the zone to be included in the Bypass Group, then press [
] to select the
zone.
3. To save the selected zone into the group, press [9][5].
4. To exit bypassing mode and return to the Ready state, press [#].
1. Press [
] to enter the function menu. The keypad will display the
screen on the right.
2. Press [1] or [
].
3. If your system is programmed to require access codes the screen on
the right will be displayed. Enter your 4-digit access code.
4. Scroll to the desired zone number using the [<][>] keys, then press [
]
to select the zone or directly enter the 2-digit number of the zone
you wish to bypass (e.g., 0 5 for zone 5).
HH:MM MM/DD/YY
09:06 01/31/11
Press (*) for <>
Zone Bypass
Enter Your
Access Code
Scroll to <>
Bypass Zones