Specifications

Appendix B
SIA Format
Level 2 (Hardcoded)
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Standard
- February 1993. This format will send the Account Code along with its data transmission. At the receiver, the transmission would
look similar to this example:
N Ri01 BA 01
N = New Event
Ri01 = Partition /Area Identifier
BA = Burglary Alarm
01 = Zone 1
PC1580 Reporting Codes SIA Identifiers &
Auto-Reporting Code
Delay Zone Alarm / Restore .................................. BA-XX / BH-XX*
Instant Zone Alarm / Restore ................................ BA-XX / BH-XX*
Interior Zone Alarm / Restore ................................ BA-XX / BH-XX*
Delay H.A. Zone Alarm / Restore.......................... BA-XX / BH-XX*
Interior H.A. Zone Alarm / Restore........................ BA-XX / BH-XX*
24 Hr Burg Zone Alarm / Restore ......................... BA-XX / BH-XX*
Standard Fire Zone Alarm / Restore ...................... FA-XX / FH-XX*
Delayed Fire Zone Alarm / Restore .......................FA-XX / FH-XX*
24 Hr Supervisory Buzzer Zone Alarm / Restore ..UA-XX/ UH-XX*
24 Hr Supervisory Zone Alarm / Restore..............UA-XX / UH-XX*
24 Hr Medical Zone Alarm / Restore ...................MA-XX / MH-XX*
24 Hr Panic Zone Alarm / Restore ........................ PA-XX / PH-XX*
24 Hr Holdup Zone Alarm / Restore .....................HA-XX / HH-XX*
24 Hr Gas Zone Alarm / Restore.......................... GA-XX / GH-XX*
24 Hr Heat Zone Alarm / Restore.......................... KA-XX / KH-XX*
24 Hr Emergency Zone Alarm / Restore ............. QA-XX / QH-XX*
24 Hr Sprinkler Zone Alarm / Restore................... SA-XX / SH-XX*
24 Hr Water Zone Alarm / Restore...................... WA-XX / WH-XX*
24 Hr Freeze Zone Alarm / Restore ...................... ZA-XX / ZH-XX*
24 Hr Latching Tamper Alarm / Restore............... BA-XX / BH-XX*
Duress Alarm ......................................................................... HA-00
Opening After Alarm..............................................................OR-00
Keypad Fire Alarm / Restore.................................... FA-00 / FH-00
Keypad Auxiliary Alarm / Restore.......................... MA-00 / MH-00
Appendix B
SIAV FORMAT
PC1580 Reporting Codes SIA Identifiers &
Auto-Reporting Code
Keypad Panic Alarm / Restore.................................PA-00 / PH-00
Zone Tamper (1-6)................................................................TA-XX*
Zone Tamper Restorals (1-6) ...............................................TR-XX*
General System Tamper / Restore........................... TA-00 / TR-00
Closing By Access Codes 1-6 .............................................. CL-XX
Partial Closing .................................................................. CG-XX
Opening By Access Codes 1-6 .......................................OP-XX
Battery Trouble Alarm / Restore............................... YT-00 / YR-00
AC Failure Trouble Alarm / Restore ......................... AT-00 / AR-00
Bell Circuit Trouble Alarm / Restore ........................ UT-99 / UJ-99
Fire Trouble Alarm / Restore ..................................... FT-00 / FJ-00
Auxiliary Power Supply Trouble Alarm / Restore ....YP-00 / YQ-00
TLM Trouble Code (via LINKS) .............................................. LT-00
General System Supervisory / Restore.................... ET-00 / ER-00
TLM Restoral .......................................................................... LR-00
FTC Restoral .......................................................................... YK-00
Event Buffer 75% Full Since Last Upload ............................. JL-00
Periodic Test Transmission ................................................... RP-00
System Test............................................................................ RX-00
LINKS1000 Test Transmission Code .....................................TX-00
General Zone Fault Alarm/ Restore ......................... UT-00 / UJ-00
Burglary Verified .................................................................... BV-00
Closing Delinquent ................................................................CD-00
* Zone Number is Identified
User Number is Identified