Specifications

27
[03] Installer’s Code (Section 4 “How to Program”)
Default Default
1575 I_______I_______I_______I_______I or 157500 I_______I_______I_______I_______II______I_______I
[04] Master Code (Section 5.1 “Programming Security Codes”)
Default Default
1234
I_______I_______I_______I_______I or 123400 I_______I_______I_______I_______II_ _____I_______I
[05] Second Master Code (Section 5.1 “Programming Security Codes”)
Default Default
AAAA I_______I_______I_______I_______I or AAAA00 I_______I_______I_______I_______II______I_______I
[06] Programmable Terminals PGM 1 & 2 (Section 5.10 “PGM Output Options”)
Default Default
02 I_______I_______I PGM1 08 I_______I_______I PGM2
Programmable Output Options
01 Ground Start Pulse 13 20 Minute Latched Alarm
02 Utility Output with Any Access Code 14 Line Seizure
([
✱] [7] [1] + [Access Code]) 15 Ready to Arm Status
03 Sensor Reset ([✱] [7] [2]) 16 LINKS Support (PGM 1 Only)
04 Courtesy Pulse 17 Downlook Support (PGM1 and PGM2 must be
05 Keypad Buzzer Follower Mode programmed with 17)
06 System Armed Status 25 For Future Use
07 Strobe Output 26 Momentary Key Switch Arm (PGM2 Only)
08 Fail to Communicate / TLM Trouble Output 27 Maintained Key Switch Arm (PGM2 Only)
09 Entry Delay Follower 28 Silent 24 Hour (PGM2 Only)
10 Exit Delay Follower 29 Audible 24 Hour (PGM2 Only)
11 TLM and Alarm 30 Forced (LINKS) Answer (PGM2 Only)
12 Police Code Follower
[07] Keypad Lockout Options (Section 5.20 “Keypad Lockout”)
Default
00
I_______I_______I Number of Invalid Codes Before Lockout
00
I_______I_______I Lockout Duration (in minutes)
[08] First System Option Code
Default Option ON OFF Section
OFF
I________I 1 Normally Closed Loops End-of-Line Resistors 2.8
OFF
I________I 2 Double End-of-Line Resistors Single End-of-Line Resistors 2.8
ON
I________I 3 [F] Key Enabled [F] Key Disabled 5.14
OFF
I________I 4 [P] Key Audible Bell and Buzzer [P] Key Silent Bell and Buzzer 5.14
ON I________I 5 TLM Enabled TLM Disabled 5.11
OFF I________I 6 TLM Audible When Armed TLM Trouble Only When Armed 5.11
[09] Second System Option Code
Default Option ON OFF Section
OFF I________I 1 Master Code Not Changeable Master Code Changeable 5.1
OFF
I________I 2 Code Required For Bypassing No Code Required 5.1
OFF
I________I 3 6th Code is Duress Code 6th Code is Normal Code 5.1
OFF I________I 4 Quick Exit Enabled Quick Exit Disabled 3.4
OFF
I________I 5 Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed 3.4
ON I________I 6 AC Trouble Displayed AC Trouble Not Displayed 3.4
P R O G R A M M I N G W O R K S H E E T S