Specifications

26
Keypad Programming
[00] Keypad Assignment (Section 2.5 “Keypad Assignment”)
Note
::
::
: This must be done at each keypad requiring programming.
[0] Slot (Valid entries are 11-18 for the Slot)
[1] - [5] Function Keys 1 to 5 Assignment (Valid entries are 00-18)
00 Null Key (Not Used) 07 [
✱✱
✱✱
✱][6][——][4] System Test 13 [
✱✱
✱✱
✱][7][1] Utility Output
01 Not used 08 [
✱✱
✱✱
✱][1] Bypass Mode 14 [
✱✱
✱✱
✱][7][2] Sensor Reset
02 Not used 09 [
✱✱
✱✱
✱
][2] Trouble Display 15 Not Used
03 Stay Arm 10 [
✱✱
✱✱
✱][3] Alarm Memory 16 [
✱✱
✱✱
✱][0] Quick Exit
04 Away Arm 11 [
✱✱
✱✱
✱][5] User Programming 17
[
✱✱
✱✱
✱][1] Reactivate Stay/Away’s
05 [
✱✱
✱✱
✱
][9] No-Entry Arm 12 [
✱✱
✱✱
✱
][6] User Functions 18 Not Used
06 [
✱✱
✱✱
✱][4] Chime On / Off
Function Function Function Function Function
Slot (Address) Key 1 Key 2 Key 3 Key 4 Key 5
1575RK defaults 11 – – – – –
PC5506 defaults 11 03 04 06 14 16
LCD5500 defaults 18 03 04 06 14 16
KEYPAD 1 I________I________I I________I I________I I________I I________I I________I
KEYPAD 2 I________I________I I________I I________I I________I I________I I________I
KEYPAD 3 I________I________I I________I I________I I________I I________I I________I
KEYPAD 4 I________I________I I________I I________I I________I I________I I________I
KEYPAD 5 I________I________I I________I I________I I________I I________I I________I
KEYPAD 6 I________I________I I________I I________I I________I I________I I________I
KEYPAD 7 I________I________I I________I I________I I________I I________I I________I
KEYPAD 8 I________I________I I________I I________I I________I I________I I________I
Zone Definitions
00 Null Zone (Not Used) 08 Standard 24 Hour Fire 15 24 Hour Medical
01 Delay 1 09 24 Hour Supervisory (LINKS) 16 24 Hour Panic
02 Delay 2 10 24 Hour Supervisory Buzzer
17
24 Hour Emergency
03 Instant 11 24 Hour Burglary 18 24 Hour Sprinkler
04 Interior 12 24 Hour Heat 19 24 Hour Water2
05 Interior, Stay/Away 13 24 Hour Gas 20 24 Hour Freeze 3
06 Delay, Stay/Away 14 24 Hour Hold-up24 LINKS Answer 21 24 Hour Latching Tamper
07 Delayed 24 Hour Fire
[01] Zone 1-6 Definitions (Section 5.2 “Zone Definitions”)
Default Default
01
I_______I_______I Zone 1 03 I_______I_______I Zone 4
06 I_______I_______I Zone 2 03 I_______I_______I Zone 5
03 I_______I_______I Zone 3 03 I_______I_______I Zone 6
[02] System Times
Default [000-255]
030
I_______I_______I_______I Entry Delay 1
045
I_______I_______I_______I Entry Delay 2
120 I_______I_______I_______I Exit Delay
004
I_______I_______I_______I Bell Cutoff
Basic System Programming
P R O G R A M M I N G W O R K S H E E T S
P R O G R A M M I N G W O R K S H E E T S