Specifications

24
P R O G R A M D E S C R I P T I O N S
if unsuccessful, the panel will try to call using the land
lines
if unsuccessful, the panel will try to call using the
LINKS
This process will continue until the panel has successfully
communicated with the central station or the Maximum
Dialing Attempts has been reached.
5.24.3 Using the LINKS as a Redundant Communicator
The panel can be programmed to call using first the land line
and then the LINKS 1000 Cellular Communicator when an
event occurs. To program this option, select both the phone
number and the LINKS options for the Communicator Call
Direction Options for the event. The Call LINKS as well as
Land Line options must be selected.
LINKS Preamble (First Telephone Number) ......... Section [67]
LINKS Preamble (Second Telephone Number) .... Section [68]
LINKS Preamble (Third Telephone Number) ........ Section [69]
LINKS Preamble
(Downloading Telephone Number) ....................... Section [79]
Communicator Call Direction Options ...... Section [51] to [55]
Call LINKS as well as Land Line ........ Section [61], Option [5]
Maximum Dialing Attempts ................................... Section [83]
5.25 On-Site Printer
With the addition of the PC5400 printer module, the panel
will print all events as they occur to a local, on-site serial
printer. All events will include the time and date when they
occured.
If a problem develops with the printer – such as power loss
or a paper shortage – the panel will store events in the Event
Buffer and print the events once the problem is corrected.
The panel can store up to 100 events if such a condition
occurs.
PC5400 Programming........................................... Section [87]
5.26 Downlook Video Transmission Module
The Number of Pictures the DLM Module will take is
programmable from one to eight.
The Delay Before Capture Timer allows the programmer to
delay the camera in taking a picture once a zone is tripped
in order to make sure that the intruder steps into the
camera’s field of view. This timer is programmed in
increments of 100 milliseconds from 00 to 99.
For more information regarding the operation of the DLM-1
and DLM-4 Modules, please refer to their respective
installation manuals.
DLM-1/DLM-4 Support Timers
(Downlook Modules) ............................................. Section [88]
Downlook will only transmit to phone number 1.
Downlook and Tx Delay must not be enabled at the
same time.
A valid zone alarm reporting code must be
programmed for zones that have Downlook enabled.
The SIA or 20BPS communications format must be
used if Downlook pictures are to be communicated
to the receiver.
5.27 Resetting Factory Defaults
On occasion, it may be necessary to default the control
panel or one of the connected modules: the ESCORT5580
module and the PC5400 Printer module.
To default the control panel (hardware) perform the
following:
1. Remove AC and battery from the panel.
2. Remove all wires from the Zone 1 and PGM1 terminals.
3. With a piece of wire short the Zone 1 terminal to the PGM1
terminal.
4. Apply AC power to the main panel.
5. When Zone Light 1 is lit on the keypad the default is
complete.
6. Remove AC power from the control panel.
7. Reconnect all original wiring and power up the control
panel.
AC power must be used to power the panel. The
panel will not default if the battery is used.
To default the control panel software and other modules,
perform the following:
1. Enter the Installer’s Programming mode.
2. Enter the appropriate programming section [XY].
3. Enter the Installer’s Code.
4. Re-enter the appropriate programming section [XY].
The panel will take a few seconds to perform the default.
When the keypad is again operational the default is complete.
Restore ESCORT to
Factory Default Programming ............................... Section [95]
Restore PC5400 to
Factory Default Programming
...............................
Section [97]
Restore Panel to Factory Default Programming
...
Section [99]
5.28 Installer’s Lockout
If Installer’s Lockout is selected, a hardware default cannot
be performed. If a software default is performed, all
programming will restore to factory default.
If Installer’s Lockout Disable is selected, the panel will
restore all programming to factory defaults when a hardware
or software default is performed on the control panel.
To enable or disable installer’s lockout, perform the
following:
1. Enter the Installer’s Programming mode.
2. Enter the appropriate programming section [XY].
3. Enter the Installer’s Code.
4. Re-enter the appropriate programming section [XY].
Installer Lockout Enable........................................Section [90]
Installer Lockout Disable ....................................... Section [91]