Specifications

17
P R O G R A M D E S C R I P T I O N S
Opening (Disarming) Reporting Codes ................ Section [42]
Opening After Alarm Keypad RingbackSection [61], Option [2]
Opening After Alarm Bell Ringback ....Section [61], Option [3]
5.7.5 Tampers
If the panel is programmed for Double EOL zones (see
Section 2.8 – “Zone Wiring”), the panel will report a Zone
Tamper Alarm Reporting Code if an open condition is
present. A different Reporting Code can be programmed to
identify each zone. The Zone Tamper Restoral Reporting
Code will be transmitted immediately when the tamper
condition is restored.
A General System Tamper Reporting Code will be
transmitted when the tamper zone on any module is violated.
The General System Tamper Restoral Reporting Code will
be transmitted when the tamper zone on the module is
restored.
Tamper Alarm Reporting Codes ........................... Section [38]
General System Tamper Alarm ............................. Section [38]
Tamper Restoral Reporting Codes ....................... Section [39]
General System Tamper Restoral ......................... Section [39]
5.7.6 Priority/Emergency
The panel will transmit a Keypad Fire Alarm Reporting
Code
and
the Keypad Fire Restoral Reporting Code when
the Fire Keys on any keypad are pressed for two seconds.
The panel will transmit a Keypad Auxiliary Alarm Reporting
Code
and
the Keypad Auxiliary Restoral Reporting Code
when the Auxiliary Keys on any keypad are pressed for two
seconds.
The panel will transmit a Keypad Panic Alarm Reporting
Code
and
the Keypad Panic Restoral Reporting Code
when the Panic Keys on any keypad are pressed for two
seconds.
The panel will transmit a Duress Reporting Code any time
the Duress Code is entered at any keypad.
Priority Alarm and Restoral Reporting Codes ......Section [40]
5.7.7 Maintenance
The panel will transmit a Battery Trouble Alarm Reporting
Code when the backup battery charge drops below 11.5
V
DC. The Battery Trouble Restoral Reporting Code will not
be transmitted until the battery has been charged to over
12.5 V
DC.
To prevent the panel from transmitting an AC Failure Trouble
Alarm Reporting Code during short power outages, the panel
will not send the signal unless AC power is lost for the amount
of minutes programmed for the AC Failure Communication
Delay. The AC Failure Trouble Restoral Reporting Code will
be transmitted as soon as AC power is restored.
A Bell Circuit Trouble Alarm Reporting Code will be
transmitted immediately when an open condition is measured
for the Bell Output of the main panel. The Bell Circuit
Trouble Restoral Reporting Code will be transmitted as
soon as the problem is corrected.
A Fire Trouble Alarm Reporting Code will be immediately
transmitted when an open condition is measured on any Fire
type zone (see Section 5.2 – “Zone Definitions”). The Fire
Trouble Restoral Reporting Code will be transmitted as
soon as the problem is corrected.
The Auxiliary Power Supply Trouble Alarm Reporting
Code will be transmitted if the AUX output is shorted out. The
AUX output of the control panel incorporates a fuseless
design. When excessive current is drawn, the panel will
automatically shut off the output. The panel will constantly
check the AUX output; when the excessive current draw is
removed, the panel will reset the output and transmit an
Auxiliary Power Supply Trouble Restoral Reporting Code.
A TLM Trouble Reporting Code can only be transmitted if a
LINKS 1000 Cellular Communicator is being used (see
Section 5.24 “LINKS 1000 Cellular Communicator”). The
panel will only transmit the signal after the time programmed
for the TLM Trouble Delay. The TLM Restoral Reporting
Code will be transmitted within 10 seconds of the problem
being corrected.
A General System Supervisory Trouble Reporting Code
will be transmitted if any module goes missing from the
KEYBUS. The panel will send a General System Supervisory
Restoral Reporting Code when the problem is corrected.
Maintenance Alarm Reporting Codes .................. Section [43]
Maintenance Restoral Reporting Codes .............. Section [44]
AC Failure Communication Delay ......................... Section [62]
5.7.8 Test Transmissions
The panel can be programmed to transmit a Periodic Test
Transmission Reporting Code (see Section 5.13 – “Test
Transmissions”), a System Test Reporting Code (see
Section 3.4 – “[✱] [6] User Functions”) or a LINKS 1000 Test
Transmission Reporting Code (see Section 5.24 – “LINKS
1000 Cellular Communicator”).
Test Transmission Reporting Codes ..................... Section [46]
5.7.9 Miscellaneous
If the panel fails to transmit information to the central station,
it will display a Failure To Communicate (FTC) trouble
condition. The panel will transmit a Phone Number 1 Failure
to Communicate Reporting Code or a Phone Number 2
Failure to Communicate Reporting Code the next time it
calls the central station. The panel will transmit the old
events, followed by the FTC message, followed by the new
events. This will allow central station to determine which
events are old or new.
If the Event Buffer is uploaded or printed on-site on a regular
basis, an Event Buffer 75% Full Reporting Code can be
transmitted to warn that the buffer is almost full. This code is
good for use with the PC5400 Printer Module.
The General Zone Fault Alarm Reporting Code is sent
whenever a DEOL hardwired zone is shorted out. The
faulted zone will also be displayed in the Trouble section.
The General Zone Fault Restoral Reporting Code will be
sent when the problem zone is repaired.
The Delinquency Reporting Code is sent whenever the
panel is not armed within the number of days programmed
for the Delinquency Transmission Delay.
Miscellaneous Maintenance Reporting Codes..... Section [45]
Delinquency Transmission Delay .......................... Section [62]
If the Delinquency Tx Delay is set for 1 day, there
must be 24 hours of no arming or disarming before
the Delinquency Code will be sent.