Control Panel Specifications
Flexible Zone Configuration:
Six fully programmable zones
Seven Access Codes: five User, one Master and a
second Master code
Normally Closed, Single EOL, Double EOL
21 Zone Types, 6 Programmable Zone Options
Audible Alarm Output:
Supervised Bell Output (current limited at 3 amps), 12 V
DC
Steady or Pulsed Output
EEPROM Memory: Does not lose programming or
system status on complete AC and Battery failure
Programmable Outputs:
Two Programmable Voltage Outputs, 22
programmable options
- One High Current (300 mA) PGM output on main
panel
- One Low Current (50 mA) PGM output on main
panel
Powerful 1 Amp Regulated Power Supply:
550 mA Auxiliary Supply, 12 V
DC
Positive Temperature Coefficient (PTC) components
replace fuses
Supervision for loss of AC Power, Low Battery
Internal Clock Locked to AC Power Frequency
Power Requirements:
Transformer = 16.5 VAC, 40VA
Battery = 12 volt 4 Ah minimum rechargeable sealed
lead acid
Remote Keypad Specifications:
Three Different Keypads Available:
- PC5506 6 Zone LED Keypad
- LCD5500 Alphanumeric Keypad
- PC1575RK 6 Zone LED Keypad
The PC5506 and LCD5500 keypads have 5 Fully
Programmable Function Keys
Connect up to 8 Keypads
Four Wire (Quad) Connection to KEYBUS
Built in Piezoelectric Buzzer
System Introduction
SECTION1
Digital Communicator Specifications:
Supports Major Formats including SIA and Contact ID
Event Initiated Personal Paging
Three Programmable Phone Numbers
Two Account numbers
Supports LINKS 1000 Cellular Communication
DTMF and Pulse Dialing
DPDT Line Seizure
Anti-jam Feature
Split Reporting of Selected Transmissions to Each
Telephone Number
System Supervision Features
The PC1580 continuously monitors a number of possible
trouble conditions including:
AC Power Failure
Trouble by Zone
Tamper by Zone
Fire Trouble
Telephone Line Trouble
Failure to Communicate
Low Battery Condition
Bell Output Trouble
Module Fault (Supervisory or Tamper)
Loss of Internal Clock
AUX Power Supply Fault
False Alarm Prevention Features
Audible Exit Delay
Audible Exit Fault
Communication Delay
Urgency on Entry Delay
Quick Exit
Additional Features
Auto Arm at Specified Time
Keypad Activated Alarm Output and Communicator
Test
All modules connect to the system via a four wire
KEYBUS up to 1000' (305 m) from main panel
Event Buffer can be printed using PC5400 RS232 Serial
Interface module
Supports the ESCORT 5580 Voice Prompt Module with
Automation/Lighting Control
An Event Buffer which records the past 100 events with
both the time and date at which they occured
Uploading and Downloading capability
• Local Downloading capability with the use of the
PC-LINK Adaptor