NOTE: Sections [81] and [82] apply only to the PC1580
v1.x. All other panels will use the reporting codes that are
programmed for these events in the panel.
[81] Miscellaneous Alarm Reporting Codes
Program 2 digit reporting codes for each of the
following reporting codes
• General Zone Fault Alarm
This code will be sent when the LINKS2150
receives a General Zone Fault Alarm event from
the PC1580.
• General System Tamper Alarm
This code will be sent when the LINKS2150
receives a General System Tamper Alarm event
from the PC1580.
• General System Supervisory Alarm
This code will be sent when the LINKS2150
receives a General System Supervisory
Alarm
event from the PC1580.
[82] Miscellaneous Restoral Reporting Codes
Program 2 digit reporting codes for each of the
following reporting codes
• General Zone Fault Restoral
This code will be sent when the LINKS2150
receives a General Zone Fault Restoral event
from the PC1580.
• General System Tamper Restoral
This code will be sent when the LINKS2150
receives a General System Tamper Restoral
event from the PC1580.
• General System Supervisory Restoral
This code will be sent when the LINKS2150
receives a General System Supervisory
Restoral
event from the PC1580.
[83] Miscellaneous Alarm Reporting Codes
(PC1565 v2.0 and PC5008 v2.0 panels only)
Program 2 digit reporting codes for the following (see your
Installation Manual for more information):
•Police Code: This code will be sent when the
LINKS2150 receives a Police Code event from the
PC1565 or PC5008.
•Delinquency Code: This code will be sent when
the LINKS2150 receives a Delinquency event from
the PC1565 or PC5008.
[96] [Installer Code] [96]
Restore LINKS2150 Factory Default
Programming for PC1580
[993][Installer Code][993]
Restore LINKS2150 Factory Default
Programming for PC5010 v1.1 or later,
PC5015, PC5008, PC1565, PC1565-2P,
PC585
When this section is successfully entered, all programming
in the LINKS2150 will be returned to the factory defaults.
NOTE: This command is unavailable on PC5010 v1.0. If
v1.0 is used, a hardware default must be done.
Hardware Reset
On a PC5010 v1.0, a hardware reset must be done. There
is no software equivalent for PC5010 v1.0.
1. Remove all power to the LINKS2150.
2. Disconnect all connections made to LB TRBL and
TRBL OUT.
3. Use a jumper to short LB TRBL and TRBL OUT
terminals.
4. Re-apply power.
5. Wait 10 seconds then remove the short.
NOTE: This can also be done if connected to PC1580.