• W A R N I N G • Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. TM Long Range Radio Alarm Transmitter Installation Manual Version 1.
Table of Contents FEATURES 1 Programmable via Keypad or Downloading Software ........................................................................................... 1 EEPROM Memory ................................................................................................................................................... 1 Static/Lightning Protection ..................................................................................................................................... 1 Supervision .
Features • Transmits alarm information to a long range radio network • Varitech Transmission Format Note: If automatic SIA is used in the panel, the reporting codes that are to be sent by the LINKS2150 must still be programmed. • May be used with the following DSC alarm control panels: • PC5010 v1.0 and up • PC5015 v1.x and up • PC5008 v2.x and up • PC1580 v1.0 and up • PC1565 v2.x and up • PC1565-2P v2.2 and up • PC585 v2.
Power Terminals + 12v – NOTE: Do not apply power to the unit until all wiring connections are completed and the antenna is attached to the unit. Connect the power terminals (+ 12V –) to the BELL+ and COM terminals or to a separate 11.5-14Vdc, 1A power supply. If you will be using a local bell or siren, use a separate power supply for the LINKS2150. Do not connect the LINKS2150 to the Keybus RED terminal.
Programming the LINKS2150 Reviewing Programmed Data Program the LINKS2150 through Installer’s Programming at a system keypad, or via DLS-1 v6.7 downloading software. • Enter the 2-digit number of the section to be reviewed. For instructions on using DLS-1 v6.7, please refer to your DLS-1 manual. • LED keypads will display the first digit of data in the section using zone lights 1 to 4 to represent the value, in binary format. To advance the display to the next digit, press the [F] key.
LINKS2150 Programming Sections These sections will only be available if a LINKS2150 v1.4W is connected to the Keybus. [86] LINKS2150 Programming Sections for PC1580 or [803] LINKS2150 Programming Section for PC5010, PC5015, PC5008, PC1565, PC1565-2P, PC585 [01] 2150 Account Code This 4-digit code is used to identify the system and is transmitted when the LINKS2150 initiates communications. Program a 4 digit code in this section using only numbers from 0 to 9.
NOTE: Sections [81] and [82] apply only to the PC1580 v1.x. All other panels will use the reporting codes that are programmed for these events in the panel. [81] Miscellaneous Alarm Reporting Codes Program 2 digit reporting codes for each of the following reporting codes • General Zone Fault Alarm This code will be sent when the LINKS2150 receives a General Zone Fault Alarm event from the PC1580.
For The Record Client ____________________________________________________________________________ Address _________________________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ Installer ______________________________ Installation Date ________________________
LINKS2150 PROGRAMMING Worksheets [86] LINKS2150 Programming Sections for PC1580 or [803] LINKS2150 Programming Section for PC5010, PC5015, PC5008, PC1565, PC1565-2P, PC585 [01] RF Identification Code Default F ______I F ______I F ______I F I______I [10] I______I______I______I______I Maintenance Alarm Reporting Codes I______I______I Internal Low Voltage Trouble I______I______I External AC Trouble I______I______I External Low Battery Trouble I______I______I Control Panel Connection Trouble I____
[81] Miscellaneous Alarm Reporting Codes I______I______I General Zone Fault Alarm I______I______I General System Tamper Alarm I______I______I General System Supervisory Alarm [82] Miscellaneous Restoral Reporting Codes I______I______I General Zone Fault Restore I______I______I General System Tamper Restore I______I______I General System Supervisory Restore Note: Sections 81 and 82 will be for 1580 v1.x only. [83] only) Miscellaneous Alarm Reporting Codes (PC1565 and PC5008 v2.
Hook-up Diagram 11
LIMITED WARRANTY Digital Security Controls Ltd. warrants that for a period of twelve months from the date of purchase, the product shall be free of defect in materials and workmanship under normal use and that in fulfilment of any breach of such warranty, Digital Security Controls Ltd. shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot.