System information
9
PROGRAMMING DESCRIPTIONS SECTION 4
[01] Module Configuration
Option 1
: Communications Enabled / Disabled
Enable this option to have the LINKS2450 initiate communications for all events that
have reporting codes and call direction options (section [30]) programmed.
Disable this option to test the system.
Option 2
: Serial Connection / Keybus Connection
Enable this option if you will use the LINKS2450 with a PC4010/4020 panel. Disable
this option if you will use the LINKS2450 with a PC5015, PC5010, PC5008, PC1580,
PC1565 or PC585 panel.
[10] LINKS2450 Account Code
This 4-digit code is used to identify the system and is transmitted when the
LINKS2450 initiates communications. Program a 4-digit code in this section using
2 two-digit Hexadecimal numbers. Refer to your control panel Installation Manual
for instructions on programming hexadecimal digits.
NOTE: An account number must be entered in this section before the LINKS2450
can send any communications. Programming [FFFF] will disable the LINKS2450.
[20] Maintenance Alarms and Restoral Reporting Codes
Program 2 digit reporting codes for the following:
• Keybus/Serial Fault Alarm:
This code will be sent when connection is lost to
the panel for more than 30seconds.
• Keybus/Serial Fault Restoral: This code will be sent when connection is
restored to the panel for more than 30seconds.
• Test Transmission: This code will be sent according to the programming of
section [40], the test transmission timer.
[30] Call Direction Options (PC5015, PC5010, PC5008, PC1580,
PC1565 and PC585 panels only)
Program which of the following reporting code types the LINKS2450 will send to the
central station:
• Alarm/restore reporting
• Tamper/restore reporting
• Opening/closing reporting
• System maintenance reporting
• System test transmission reporting
In most installations, you should program the tranmission of alarm/restore reporting codes
only. Your radio network has limited bandwidth and capacity. The more signals each
LINKS2450 transmits, the fewer LINKS2450s you will be able to install on your network.
[40] Test Transmission (Heartbeat) Timer
Use this feature with appropriately equipped Safe Link radio networks to provide
a higher level of security to a limited number of radios. The LINKS2450 will send test
signals at the interval programmed in this section. If the network does not receive
a test signal, an exception signal is generated and sent to your central station.