System information
6
PROGRAMMING THE LINKS2450
Section 3
See section 3.1 for programming instructions when connecting the LINKS2450 to
a PC5015, PC5010, PC5008, PC1580, PC1565 or PC585 panel. See section 3.2 for
programming instructions when connecting the LINKS2450 to a PC4010 or PC4020
v3.0 panel.
3.1 Programming a LINKS2450 Connected to a PC5015, PC5010,
PC5008, PC1580, PC1565 or PC585 Panel
Program the LINKS2450 through Installer’s Programming at a system keypad. For
instructions on using Installer’s Programming sections, please refer to Section 4
“How to Program” in your control panel Installation Manual.
1. Go to Installer’s Programming by entering [*][8][Installer’s code].
2. For PC5015, PC5010, PC5008, PC1565 and PC585:
Go to the LINKS2450
programming section by entering [803]. Program the following sections only
(see section 4 for a description of each section). Record your programming
choices in the worksheets at the end of this manual.
[01] Module Configuration
Option 1
: Communications Enabled / Disabled
Option 2
: Serial Connection / Keybus Connection
[10] LINKS2450 Account Code
[20] Maintenance Alarms and Restoral Reporting Codes
[30] Call Direction Options
[40] Test Transmission (Heartbeat) Timer
[83] Miscellaneous Alarm Reporting Codes (PC1565, PC5008 v2.0
panels only)
3. For PC1580:
Go to the LINKS2450 programming section by entering [86].
Program the following sections only. See section 4 for a description of each
section. Record your programming choices in the worksheets at the end of
this manual.
[01] Module Configuration
Option 1
: Communications Enabled / Disabled
Option 2
: Serial Connection / Keybus Connection
[10] LINKS2450 Account Code
[20] Maintenance Alarms and Restoral Reporting Codes
[30] Call Direction Options
[40] Test Transmission (Heartbeat) Timer
[81] Miscellaneous Alarm Reporting Codes (PC1580 panel only)
[82] Miscellaneous Restoral Reporting Codes (PC1580 panel only)
4. To exit Installer’s Programming, press [#].