System information
12
RESET LINKS2450 PROGRAMMING TO FACTORY
DEFAULT Section 6
If you need to reset the LINKS2450 to factory default programming, follow the
directions in the appropriate sections below.
6.1 Reset the LINKS2450 on a PC1580 Panel
To reset the LINKS2450 on a PC1580 panel, enter [96] [Installer’s Code] [96].
6.2 Reset the LINKS2450 on a PC5015 v2.2, PC5010 v2.0,
PC5008, PC1565 or PC585 Panel
To reset the LINKS2450 on a PC5015 v2.2, PC5010 v2.0, PC5008 or PC1565 panel,
enter [993] [Installer’s Code] [993].
NOTE: This command is unavailable on PC5010 v1.0. If v1.0 is used, you must
perform a hardware reset (see section 6.3 below).
6.3 Perform a Hardware Reset (All panels)
To reset the LINKS2450 when connected to a PC5010 v1.0 or a PC4010/4020
panel, you must perform a hardware reset. To do this:
1. Remove all power from the LINKS2450
2. Short jumper J3
3. Remove all wires from the YEL and GRN terminals
4. With a piece of wire, short the YEL terminal to the GRN terminal
5. Apply power to the LINKS2450 for 5 seconds.
6. Remove power from the LINKS2450
7. Reconnect all original wiring and re-power the LINKS2450
NOTE: If the LINKS2450 is connected to a PC4010/4020 panel, the programming
done in the panel software will not be reset. See section 3.2, step 5 for information
on re-programming the PC4010/4020 sections.