System information
10
Special procedures are necessary to activate this feature for a radio account.
Check with Safe Link for more information.
Program the amount of time in minutes (000-255) between LINKS2450 test
transmissions. Program this section as a two-digit hexadecimal number. Refer to
your control panel Installation Manual for instructions on programming hexadeci-
mal digits. If you program [00], the LINKS2450 will not send a test transmission.
In most installations, you should limit the number of LINKS2450s which send test
signals and the number of test signals each LINKS2450 sends. Your radio network
has limited bandwidth and capacity. The more signals each LINKS2450 transmits, the
fewer LINKS2450s you will be able to install on your network.
[81] Miscellaneous Alarm Reporting Codes (PC1580 panel only)
Program 2 digit reporting codes for the following:
• General Zone Fault Alarm: This code will be sent when the LINKS2450
receives a General Zone Fault Alarm event from the PC1580.
• General System Tamper Alarm: This code will be sent when the LINKS2450
receives a General System Tamper Alarm event from the PC1580.
• General System Supervisory Alarm: This code will be sent when the
LINKS2450 receives a General System Supervisory Alarm event from the
PC1580.
[82] Miscellaneous Restoral Reporting Codes (PC1580 panel only)
Program 2 digit reporting codes for the following (see your PC1580 Installation
Manual for more information):
• General Zone Fault Restoral: This code will be sent when the LINKS2450
receives a General Zone Fault Restoral event from the PC1580.
• General System Tamper Restoral: This code will be sent when the
LINKS2450 receives a General System Tamper Restoral event from the
PC1580.
• General System Supervisory Restoral: This code will be sent when the
LINKS2450 receives a General System Supervisory Restoral event from the
PC1580.
NOTE: Sections [81] and [82] apply to the PC1580 only. All other panels will use
the reporting codes that are programmed for these events in the panel.
[83] Miscellaneous Alarm Reporting Codes (PC1565 v2.0,
PC5008 v2.0 panels only)
Program 2 digit reporting codes for the following (see your PC1565 Installation
Manual for more information):
• Police Code: This code will be sent when the LINKS2450 receives a Police
Code event from the PC1565 v2.0 or PC5008 v2.0.
• Delinquency Code: This code will be sent when the LINKS2450 receives a
Delinquency event from the PC1565 v2.0 or PC5008 v2.0.