SDS

Occupational exposure limit values (Workplace Exposure Limits)
Coun-
try
Name of agent CAS No Identi-
fier
TWA
[ppm]
TWA
[mg/m³]
STEL
[ppm]
STEL
[mg/m³]
Ceiling-C
[ppm]
Ceiling-C
[mg/m³]
Nota-
tion
Source
US titanium dioxide 13463-67-7 PEL 15 i, dust 29 CFR
1910.10
00
US titanium dioxide 13463-67-7 REL lowest,
appx-A
NIOSH
REL
US Titanium dioxide
finescale particles
13463-67-7 TLV® 2.5 r ACGIH®
2022
US Titanium dioxide
nanoscale
particles
13463-67-7 TLV® 0.2 r ACGIH®
2022
US quartz 14808-60-7 PEL
(CA)
0.05 r Cal/
OSHA
PEL
US silica, crystalline -
quartz
14808-60-7 PEL 0.05 r 29 CFR
1910.10
00
US silica, crystalline -
quartz
14808-60-7 REL 0.05
(10 h)
r, appx-
A
NIOSH
REL
Notation
appx-A NIOSH Potential Occupational Carcinogen (Appendix A)
appx-D see Appendix D - Substances with No Established RELs
Ceiling-C ceiling value is a limit value above which exposure should not occur
dust as dust
i inhalable fraction
lowest exposure by all routes should be carefully controlled to levels as low as possible
noAsb_less1
Sil
contains no asbestos and less than 1% free crystalline silica
r respirable fraction
STEL short-term exposure limit: a limit value above which exposure should not occur and which is related to a 15-minute peri-
od (unless otherwise specified)
TWA time-weighted average (long-term exposure limit): measured or calculated in relation to a reference period of 8 hours
time-weighted average (unless otherwise specified
8.2 Exposure controls
Appropriate engineering controls
General ventilation.
Individual protection measures (personal protective equipment)
Eye/face protection
Wear eye/face protection.
Skin protection
- Hand protection
Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. Check leak-
tightness/impermeability prior to use. In the case of wanting to use the gloves again, clean them before taking off
and air them well. For special purposes, it is recommended to check the resistance to chemicals of the protective
gloves mentioned above together with the supplier of these gloves.
- Other protection measures
Take recovery periods for skin regeneration. Preventive skin protection (barrier creams/ointments) is recommended.
Wash hands thoroughly after handling.
Respiratory protection
In case of inadequate ventilation wear respiratory protection.
Safety Data Sheet
acc. to 29 CFR 1910.1200 App D
DRYLOK® Latex Concrete Floor Paint (Cream) 50g/l
Version number: REV 1.0 Date of compilation: 2022-05-24
United States: en
Page: 6 / 14