Specification
1.  For  each  product  specified,  two  cured  samples,  representing  actual  product  color  and 
texture. 
1.5  QUALITY ASSURANCE 
A.  Comply with Section 01 40 00. 
B.  Qualifications: 
1.  Manufacturer  Qualifications:    Company  with  minimum  15  years  of  experience  in 
manufacturing of specified products and systems. 
2.  Applicator Qualifications: Company with minimum of 5 years’ experience in application 
of products as specified in this section on projects of similar size and scope, and employs 
installers and supervisors who are trained by and acceptable to product manufacturer. 
a.  Successful completion of a minimum of 5 projects of similar size and complexity 
to specified Work. 
C.  Field Mock-up: 
1.  Install  at  Project  site  or  pre-selected  area  of  building  an  area  for  field  mock-up,  as 
directed by Architect. 
2.  Apply material in strict accordance with manufacturer’s written application instructions. 
3.  Manufacturer’s representative or designated representative will review technical aspects; 
surface preparation, application, and workmanship. 
4.  Field sample will be standard for judging workmanship on remainder of Project. 
5.  Maintain field mock-up during construction for workmanship comparison. 
6.  Do not alter, move, or destroy field mock-up until Work is completed and approved by 
Architect. 
7.  Obtain Architect’s written approval of field mock-up before start of material application, 
including approval of aesthetics, color, texture, and appearance. 
1.6  DELIVERY, STORAGE, AND HANDLING 
A.  Comply with Section 01 60 00. 
B.  Comply  with  manufacturer’s  ordering  instructions  and  lead-time  requirements  to  avoid 
construction delays. 
C.  Deliver  materials  in  manufacturer's  original,  unopened,  undamaged  containers  with 
identification labels intact. 
D.  Transport and store in unopened containers and keep in clean, dry condition protected from rain, 
dew, and humidity. 
1.7  PROJECT CONDITIONS 
A.  Environmental Requirements: 
1.  Do not apply outdoors in rain or when rain is expected within 48 hours.  Do not apply 
above  95  degrees  F  (35  degrees  C)  or  below  50  degrees  F  (10  degrees  C)  or  when 
temperatures are expected to fall below 40 degrees F (4 degrees C) within 24 hours. 