Data Sheet

6
1
Vibration
Test
振动
NO explosion,no fire,no
leakage
不起火、不爆炸、不泄
After Standard Charging,fixed the cell to vibration
table,then
subjected to vibration test for 30 minutes per axis of
XYZ axes
Frequency rate :1 Oct/min
Vibration frequency : 10Hz-30Hz
Excursion(single amplitude): 0.38mm
Vibration frequency : 30Hz-55Hz
Excursion(single amplitude): 0.19mm
电芯标准充电后,固定在振动台上,然后沿
XYZ
每个
坐标方向振动 30 分钟
扫频速率:
1 O
ct/min
振动频率:
1
0Hz-30Hz
位移幅值(单振幅):0.38mm
振动频率:
3
0Hz-55Hz
位移幅值(单振幅):0.19mm
2
Drop Test
跌落测试
NO explosion,no fire,no
leakage.
不起火、不爆炸、不泄
漏。
Drop the battery in the shipment condition from 1m
height onto 18~20mm thick hard board on it 3 times
each of X,Y,and Z directions at 25±2
在出货条件下将电池从高度1的位置自由跌落到
18-20毫米厚的硬质木板上XYZ向上各三次
4.3Test data 测试数据
Charge0.5C CC(constant current)charged to4.2V, then CV(constant voltage 4.2V)charge till charge current
decline to0.05C at 25
充电:在 25下,用 0.5C CC(恒流)充电至 4.2V,再 CV(恒压)充电直至充电电流0.05C
Continuous Discharge1C CC3.0Vcut-offat 25
持续放电:1C 恒流放电到 3.0V 截止, 25