ULTRA FLAME DIRECT VENT GAS STOVE INSTALLATION AND OPERATING INSTRUCTIONS FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE FOR YOUR SAFETY IF YOU SMELL GAS: 1. OPEN WINDOWS 2. TURN OFF MAIN GAS SUPPLY 3. DON'T TOUCH ELECTRICAL SWITCHES 4. EXTINGUISH ANY OPEN FLAME 5. IMMEDIATELY CALL YOUR GAS SUPPLIER Manufactured by : Tested by : DROLET STOVES & FIREPLACES INC.
TABLE OF CONTENTS : TABLE OF CONTENTS : ........................................................................................... 2 GENERAL INFORMATION : .................................................................................... 3 WARNING .................................................................................................................. 4 SPECIFICATIONS : ....................................................................................................
GENERAL INFORMATION : The ULTRA FLAME DIRECT VENT GAS STOVE is a high-efficiency free-standing gas appliance with a maximum input rating of 30 000 Btu/h with natural gas or 26,000 Btu/h with propane. It features a thermostatic modulating valve and a constant pilot. This means that the flame will vary in height according to room temperature. The colder the ambient temperature the larger the flames. The valve is also independent of any exterior electrical supply.
WARNING INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER. DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THIS APPLIANCE. HOT WHEN IN OPERATION. KEEP CHILDREN, FURNITURE, CLOTHING AND FLAMMABLE MATERIAL AWAY FROM THE APPLIANCE. ADVISE ADULTS AND CHILDREN TO THE HAZARD OF HIGH SURFACE TEMPERATURES AND THAT THEY SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
SPECIFICATIONS : Dimensions : height : width : depth : Glass : 29-3/16" 26-5/16" 19-5/8" front 18-3/16" x 15-31/32" 1400oF clear ceramic sides 5-1/16" x 15-31/32" 1400oF clear ceramic Fuel : Input : Manifold pressure : Min inlet pressure : Max. inlet pressure : Natural Gas 30 000 3.5 5 7 Propane 26 000 10 11 14 Btu/h in w.c. in w.c. in w.c. Vent size : 5" inner 8" outer coaxial vent pipes for straight out and corner kits installation.
TOP, FRONT AND SIDE VIEWS : INSTALLATION: 26-5/16" 13-5/32" 8" 5" 19-5/8" Top view 26-5/16" 17-1/2" 19-5/8" 2-5/8" 6-1/8" 18-7/8" 13-5/8" 29-3/16" 10-5/16" 24-1/8" Front view 18-1/4" Side view 6
INSTALLATION SAFETY NOTICE : Improper installation may result in a house fire. Follow installation directions. Installation must be in accordance with local building codes and with current CAN/CGA B149.1 & B149.2 installation codes for gas appliances. INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER. THIS GAS FIREPLACE MUST BE VENTED OUTSIDE. The gas stove must be electrically grounded in accordance w ith the current CSA C22.1 Canadian Electrical Code.
L9002.
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings * Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor * * As specified in CGA B149 Installation Codes (1991) NOTE: Local codes or Regulations may require different clearances In addition, the following restrictions also apply.
Clearance between the stove and any combustible material must also be respected while installing your appliance. Clearance to the floor is 0". Clearance between wall and the pipe is 1". Do not install pipe in an enclosed area or through an insulated wall without a radiation shield ( no E-5710) INSTALLATION OF THE UNIT • Move the ULTRA FLAME to the desired position. Mark the location for the gas inlet pipe and the location where the vent pipes will go through the wall. Remove the appliance.
CONNECT THE POWER LINE TO THE SAME WIRES THE CORD WAS CONNECTED TO (P) P G P JUNCTION BOX SPEED CONTROL • If you prefer to use the six-foot cord supplied, just connect it to a 120V outlet. • Move the ULTRA FLAME to the desired position and secure in place with four screws. • Connect the gas line to the stainless steel flex connector supplied. PLUGGED TAPPING SHUT OFF VALVE GAS VALVE STEEL GAS LINE FLEX CONNECTOR • Check the gas line piping for leaks. Use a soap and water solution.
VENTING KITS Once the position of the stove and the termination cap are fixed, you should select the venting kit appropriate for your needs. First floor installations require either a STRAIGHT OUT kit or a CORNER kit while basement installations must be done with a BASEMENT kit. Please note that the BASEMENT kit can also be used on first (or higher) floors and it is possible to use up to 25' of pipe with a distant installation.
• Add a spring spacer. Spring spacer must be located opposite to the joints of the outside pipe to prevent puncturing of the inside pipe when screwing two sections of the outside pipe together. • Add sections of 8" diameter pipe and cut it to be flush with the outside face of exterior wall, and install them to the 45° elbow, throught the radiation shield. • Seal the 8" diameter pipes and elbows joints with silicone. • The installation inside the house is now completed.
VENTING KITS Straight out Corner VENT TERMINAL VENT TERMINAL RADIATION SHIELD 45 O ELBOW 60" MAX RADIATION SHIELD -min 1" -max 60" VENT PIPES Basement 10-1/2" X 10-1/2" OPENING CUT TO LENGTH .
5" LOCKING BAND SCREWS 8"RIGID AIR INLET PIPE 5" FLEXIBLE FLUE PIPE 4" FOR BASEMENT OR DISTANT INSTALLATION 4) DISTANT INSTALLATION It is possible to use up to 25 feet of pipe and a wall vent terminal or roof vent terminal ( no E5700 ) However, the following restrictions must be applied. (see figure, next page) - Maximum vertical lenght is 10 feet with the wall vent terminal.
L9001.
VENT TERMINAL STRAIGHT OUT AND CORNER INSTALLATION Seal with RTV silicone between 8" diameter pipe and radiation shield inside and outside the building to prevent air passage. Install the vent terminal as shown. Insert the wall plate inside the 8" pipe and screw it to the wall using the six #10 2-1/2" wood screws supplied. Place the 5" locking band around the inner connector and insert the exhaust pipe. Sealing the joint with RTV silicone. Secure the pipe in place with one #10 1/2" metal screw.
VENT TERMINAL, ROOF INSTALLATION • Here are the distance requirements for roof terminal installation. • Clearance between combustible wall and vent pipe must be 2" and a radiation shield must be use to cross and insulated wall. • If vent terminal is more then 5 feet above the roof use roof braces to secure the whole assembly INSTALLATION OF SIDE PANELS AND PEDESTAL • Remove the three nuts on each side of the stove. • Place both panels in position and only screw the nuts back on manually.
NUTS Pedestal cover : Slide the pedestal cover over the pedestal from the front. Place the back cover on the pedestal cover and secure with the supplied screws. PEDESTAL COVER BACK COVER SCREWS • The paint on your stove will produce light smoke and fumes when heated for the first time. We recommend you light the stove and let it burn for at least an hour while providing good ventilation in the room. This will cure the paint and help preserve its quality.
GLASS FRONT REMOVAL, CLEANING AND INSTALLATION GLASS FRONT ASSEMBLY SIDE PANELS DECORATIVE GOLD TRIMS CLAMPS (OPEN POSITION) Removal : - Let the stove cool down for at least one hour. - Remove the decorative gold trim from the stove. - Open both side panels. - Open the four clamps. - Remove the glass front assembly. CAUTION : Do not operate your fireplace without a glass front or with a broken glass. Cleaning : - Only clean the glass when cold.
BURNER REMOVAL AND INSTALLATION : SQUARE HOLE BURNER REMOVAL : -Remove the glass front assembly as shown on page 20. -Slide the burner to the left and pull toward you. INSTALLATION : VENTURI TUBE MAIN ORIFICE AIR SHUTTER Put the burner assembly back in the fire box and push to the right. Make sure the main orifice is inserted in the venturi tube by looking through the square hole shown. There should be no gap between the venturi tube and the orifice assembly.
LOG INSTALLATION : 1. Remove the glass front as described on page 20. 2. Install the longer log in back of the firebox with locating grooves on top. 3. Install the 14" log in the front of the firebox and to the right. Make sure the log is pushed against the metal retainer on the burner face. 4. Place the front of the log with a hole in the first notch from the left in the log holder at the front of the burner and position its back in the back log groove. It should be touching the 14" log. 5.
EMBER KIT INSTALLATION : Threesmall plastic bags are supplied with your unit. One of the bags contains vermiculite to simulate ashes in the fire box, another contains lava rock to simulate coals and the last one is filled with rock wool fibre which, when glowing red, resembles hot embers. (follow instruction on the next drawing) 1. Place some vermiculite and some lava rocks at the bottom of the fire box and on top of the burner plate. Never put to much of these material on the burner.
REFRACTORY PANELS INSTALLATION: 1. Remove the glass front assembly. 2. Remove the logs from the firebox. 3. Place the back refractory against the back of the firebox. 4. Install the two side refractory panels by sliding them between the firebox sides and the baffle plate. 5. Put the logs back in place. 6. Install the glass front assembly. GOLD TRIM INSTALLATION: Slide both trim pieces from the front over the edges of the stove firebox .
OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS: 1. Open the pedestal cover front panel to reach the control. 2. Turn the gas valve knob to the "OFF" position and wait 5 minutes. 3. Turn the gas valve knob to "PILOT". 4. Depress and hold the knob while lighting the pilot by pressing the pilot igniter button (RED button right of the valve). Keep the knob depressed for about 30 seconds. Release the knob. The pilot should continue to burn by itself. If not, repeat step 4.
NOTE : This valve is equipped with a modulating thermostat that will automatically adjust flame height according to room temperature. As room temperature approaches the value set by the knob ( anywhere between HI and LOW on the knob ), the flame will decrease in height. When the room reaches the set temperature, the flame will go out. To restart flame, turn the knob to a higher setting or wait for room temperature to decrease below actual setting.
MAINTENANCE INSTRUCTIONS : TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. The venting system and the gas stove should be inspected at least once a year. Remove the glass front and the logs and clean them if necessary. The control compartment, air circulating passages, firebox, logs and burner should be cleaned at least once a year by vacuuming or brushing. Check the pilot flame to see if it is adjusted properly.
OPTIONAL PARTS ITEM DESCRIPTION Pedestal and side panels almond enamel Pedestal and side panels black enamel Pedestal and side panels black painted Decorative refractory kit Gold plated door trims QTY 1 1 1 1 1 REPLACEMENT PARTS ITEM DESCRIPTION 4 Log kit Burner assembly Burner orifice, ( natural gas or propane ) Pilot assembly, ( natural gas or propane ) S.I.T. Thermocouple S.I.T. Piezo igniter S.I.T.
LIMITED 5 YEARS WARRANTY ______________________________________________ DROLET STOVES AND FIREPLACES INC. hereby warrants the quality of its ULTRA FLAME direct vent gas stove against manufacturing defects. The product shall be delivered to the buyer in good condition and the latter should inform the vendor immediately of any defect in the product delivered. During the first year of the limited warranty, DROLET STOVES AND FIREPLACES INC.