Technical data

Page 3 of 15
INSTALLATION INSTRUCTIONS
LOCATING THE APPLIANCE
Position the appliance as close as possible to the chimney.
Many configuration are possible, the most frequent are illustrated in figures 1,2 and 3.
Respect clearances indicated on page 1. They have been tested according to approvals.
Always respect clearances of appliance pipe manufacturers. Larger clearances always prevail.
Figure 1 : CORNER INSTALLATION
Figure 2 : PARALLEL INSTALLATION
Figure 3 : WALL INSTALLATION
Table 1 : CLEARANCES TO COMBUSTIBLES
mm in
Back 180 7
Side 150 6
Corners 150 6
Top 915 36
Flue Pipe 230 9
IMPORTANT: It is essential to ensure that the room in which the appliance is installed is sufficiently
ventilated to provide an adequate air supply.
It is possible that if your home is well insulated, that you will have to install an outside fresh air intake.
THE BURNING OF ONE LITRE OF FUEL (OIL) REQUIRES APPROXIMATELY 30 M
3
OF AIR AND WILL
PRODUCE ABOUT 0.8 KG OF WATER OF WATER VAPOR AND 9 M
3
OF CARBONE DIOXIDE AND
ATMOSPHERIC NITROGEN. A SOURCE OF AIR FROM THE OUTSIDE IS NEEDED TO REPLACE
COMBUSTION AIR.