Your stove must be mounted on fireproof surface. If you have decided to mount it on an area
where flooring material is not fireproof, then you must add a panel of asbestos between the stove
and the floor. The thickness and dimensions of this panel differ according to each model, as
outlined in the following chart.
__________________________________________________________________________
Model Thickness Panel Panel Panel
of Protrusion Protrusions Protrusion
panel at front at sides at back
__________________________________________________________________________
Lorraine 3/8" (7mm) 18" (457mm) 6" (150mm) 6" (150mm)
__________________________________________________________________________
Cassandra & 3/8" (7mm) 18" (457mm) 6" (150mm) 6" (150mm)
Janet
__________________________________________________________________________
Note: Asbestos panel can be replaced by a ceramic of gauge 18 sheet metal.
1) Whether you choose to install your stove cornerwise in a room or parallel to a wall, you must
adhere to the specifications for distances to be respected. These are clearly illustrated for
each particular model.
Lorraine..............................................................................................................drawing #1
Cassandra & Janet..............................................................................................drawing #1
2) Note : Only competent authorities can approve shorter distances.
3) Avoid placing wood or other inflammable substances too close to your heating unit. As we
have already stipulated, make sure that the proper distances are respected between your unit
and any inflammable substances.