OPERATION MANUAL ECO-55 / ECO-55 CT / ECO-55 ST
ENGLISH
7. VENTING SYSTEM MAINTENANCE
CAUTION
REGULARLY EXAMINE THE VENTING
SYSTEM, THE JOINTS, AND THE SEALING
TRIMS TO ENSURE THAT THE SMOKE
AND THE COMBUSTION GASES ARE NOT
LEAKING.
Chimney cleaning can be a difcult and dangerous
job. If you don’t have experience cleaning chimneys,
you might want to hire a professional chimney sweep
to clean and inspect the system for the rst time. After
having seen the cleaning process, you can decide if
it is a job you would like to take on.
The most effective method of sweeping the vent
system is to use a 3" or 4" brush, depending on
your installation. Start at the top of the vent system
and brush down, so that the ash, soot and creosote
residues come off the inner surface and fall into
the bottom of the vent system, where they can be
removed easily.
The vent system must be kept in good condition and
well maintained.
CAUTION
IF A SIGNIFICANT LAYER OF
CREOSOTE HAS ACCUMULATED (3 MM
/ 1/8" OR MORE), IT MUST BE REMOVED
IMMEDIATELY TO ELIMINATE THE RISK
OF A CHIMNEY FIRE.
FACING A CHIMNEY FIRE
1. Evacuate family members and animals from the
building, then call the re department.
2. Turn off the unit. Do not unplug it!
3. If possible, use a chemical re extinguisher,
baking soda or sand to control the re. Do not
use water, as this may cause hazardous vapor
explosions.
4. Do not use the stove until the vent system and
the stove have been inspected by a qualied
chimney sweeper or re inspector.
7.1 SOOT AND FLY ASHES
The combustion products contain small particles
of y ash. Fly ash can accumulate especially in
horizontal sections of exhaust pipe and restrict the
ow of combustion gases. Incomplete combustion,
8. TROUBLESHOOTING
NOTICE
VISIT OUR WEB SITE TO OBTAIN A DETAILED
TROUBLESHOOTING DOCUMENT.
Most common problems are generally caused by the
following factors:
1. Wrong operation or lack of maintenance;
2. Bad installation;
3. Poor quality combustible;
4. Component failure;
The stove is equipped with a pc board that allows
the stove to diagnose itself. It is thus important not
to unplug the stove if there is an issue with it. First,
because unplugging the stove will disable all the
security features of the stove, and second, because
you will not be able to see the error code given by the
stove to understand what the problem is.
8.1 PRINCIPAL ERROR CODES
Code Description
P
Blocked ue. Make sure that the vent system
is installed properly. Press the «RESET»
button to reset the stove and «MODE» to
restart it.
H
The stove is overheating. Service the
unit and inspect the venting system.
Press the «MODE» and «RESET» button
simultaneously for 3 seconds to reset the
stove.
If more than one H code occurs, refer to
section «Signs of overheating».
E
The hopper is empty. When all components
are stopped, press the «RESET» button.
Fill the hopper and press the «AUGER»
button. Press «MODE» to restart the stove.
produced when igniting, shut down or misuse of
the stove will cause some soot formation which
can accumulate in venting system. The venting
system must be inspected at least twice a year to
determine if cleaning is necessary.