Installation Guide
Page 7
INSTALLATION MANUAL ECO-55 / ECO-55 CT / ECO-55 ST
ENGLISH
3. CLEARANCES TO COMBUSTIBLE
MATERIALS
The clearances shown in this section applies to
DP00070, DP00072 and DP00071.
The clearances shown in this section have been
determined by tests according to procedures set out in
safety standards ULC S627 (Canada), ASTM E1509
(U.S.A) and UL1482 (U.S.A.). When the pellet stove
is installed so that its surfaces are at, or beyond, the
minimum clearances specied, combustible surfaces
will not overheat under normal and even abnormal
operating conditions.
WARNING
NO PART OF THE PELLET VENT SYSTEM MAY
BE LOCATED CLOSER TO COMBUSTIBLES
THAN THE MINIMUM CLEARANCES SPECIFIED
BY THE VENT MANUFACTURER.
WARNING
NO PART OF THE STOVE MAY BE LOCATED
CLOSER TO COMBUSTIBLES THAN THE
MINIMUM CLEARANCES SPECIFIED ON THE
CERTIFICATION LABEL.
NOTICE
The following clearances are also valid for an
alcove installation. However, if the stove is
installed in an alcove, to perform maintenance, you
should expect to move the appliance to get to the
maintenance access doors and components.
3.1 CLEARANCES TO COMBUSTIBLES
MATERIALS, WALLS AND CEILING
MINIMUM CLEARANCES
CANADA USA
A*
3" (76 mm) 3" (76 mm)
D
Note 1 Note 1
I**
48" (1 220 mm) 48" (1 220 mm)
*From the rear panel
**Measured from the platform on which the product is installed.
RECOMMENDED CLEARANCES FOR
MAINTENANCE
CANADA USA
A*
12" (305 mm) 12" (305 mm)
MINIMUM CLEARANCES
CANADA USA
B
6" (152 mm) 6" (152 mm)
D
Note 1 Note 1
RECOMMENDED CLEARANCES FOR
MAINTENANCE
CANADA USA
B
24" (610 mm) 24" (610 mm)
Note 1 : Refer to the exhaust venting system manufacturer’s
instructions for clearances to combustible materials.