4. Air intake channel is
restricted.
Visually inspect the air intake channel that leads to the burn pot for
foreign material. Make sure that the air-intake shutter is functional
and free of any obstruction.
5. The
combustion/exhaust
blower failed.
See Section 8.2: Testing a Component and test the combustion
and the exhaust blowers independently. If one of them does not
function, make sure there is power and that the blowers are
properly connected. If they still don’t work, check fuse F4 and F5
on the control board. A blown fuse will be darkened or will have a
broken filament. If the fuses are in good condition, the combustion
or exhaust blower is probably defective. Replace the faulty part.
8.3.13 No Display
The control board does not display any information.
Possible Cause:
Possible Remedy :
1. There is no electrical current going to the
stove.
Check if the stove is connected and if there is
current in the wall outlet. Check if the F7 fuse
is blown. Replace it if necessary.
2. TELCO wire is defective or not connected
properly.
Convection blower, combustion blower,
exhaust blower and burn pot auger will start
but the stove will beep continuously. Verify
the connection between the control panel and
the electronic card. Change wire if necessary.