Use and Care Guide

Eco-65 Installation and Operation Manual
54
NOTE: IF THE CODE APPEARS MORE THAN THREE TIMES, THE ERROR CODE WILL
LOCK ITSELF UP.
THIS PELLET STOVE IS EQUIPED WITH MULTIPLE DEVICES TO ENSURE YOUR
SAFETY. IF A WARNING ERROR CODE STOPS YOUR STOVE ON SEVERAL
OCCASIONS, IT IS MORE THAN LIKELY THAT THE STOVE DOES NOT EXHAUST
PROPERLY.
COMPLETE the stove maintenance as described in this manual before
resetting the electronic board displaying an error code.
For an Overheat Code
Service the stove COMPLETELY as described in this manual. See
section 7 : Maintenance
Verify the complete venting system.
FOLLOW THESE INSTRUCTIONS ONCE THE MAINTENANCE COMPLETED
Press on the following buttons in the sequence given (one button at a time).
« Reset » then « Mode » then « + » then « - » and hold
« Auxiliary » for 3 seconds. The system will reset.