Push the control key to proceed.
The frequency of the power source is displayed. Push any
control key to proceed.
The tension of the power source is displayed. Push any
control key to proceed.
Displays if polarity is good (POLP)
If polarity is reversed (POLF). Push any control key to
proceed.
The version of software included in the control board is
displayed. Push any control key to proceed.
Displays the status of different components.
OFF DEL: Pressure switch
MANUAL DEL: Hopper switch
THERMOSTAT DEL: Wall thermostat
FEED RATE 1 : (non operative)
FEED RATE 2 : F160
FEED RATE 3 : L250
FEED RATE 4 : (non operative)
FEED RATE 5 : auger # 2 fuse
FEED RATE 6 : igniter fuse
Note :
- DEL ON = open circuit
- DEL ON = blown fuse
- DEL OFF = close circuit
- DEL OFF = fuse good
Push any control key to proceed.
SPARE output testing section.
(NOT OPERATIVE ON THIS VERSION)
Push any control key to proceed.
« Zero current » test used by the control board. Push any
control key to proceed.