Use and Care Guide

Eco-65 Installation and Operation Manual
17
Canada:
Letter
Min.
clearances
Description
A
12’’ (30 cm)
Clearances above grade level or any adjacent surface that might
support snow, ice, or debris
B
39’’ (100 cm)
Clearance to window or door that may be opened
F
39’’ (100 cm)
Clearance to corner or adjacent wall
H
39’’ (100 cm)
Not to be installed above a meter/regulator assembly within 39" (100
cm) horizontally from the vertical center-line of the regulator and for 15’
vertically
I
72’’ (183 cm)
Clearance to gas service regulator vent outlet or within 39’’ (100 cm) of
an oil tank vent or an oil tank fill inlet
J
39’’ (100 cm)
Clearance to the combustion air inlet to any other appliance
K
72’’ (183 cm)
Clearance to a mechanical air supply inlet
L
84’’ (213 cm)
Clearance above paved side-walk or a paved driveway located on
public property
39’’ (100 cm)
Clearance to property boundary
A vent shall not terminate underneath a veranda, porch, or deck
United States:
Not Less than 36’’ (91 cm) above any forced air inlet located within 10 feet (305 cm);
Not Less than 48’’ (122 cm) below and horizontally from, or one foot (30 cm) above, any
door, window or gravity air inlet into any building;
Not Less than 24’’ (61 cm) from an adjacent building and not less than 84’’ (213 cm)
above grade when located adjacent to a public walkway.
Cannot be located less than 12 inches (300mm) above grade.
Cannot be located above a gas meter/regulator within 3 feet (900mm) horizontally of the
vertical center line of the regulator.
Not within 6 feet (1.8 meters) of a gas service regulator vent outlet.
Other restrictions may apply. See NFPA 211 for further information.
4.5 Installation Configurations
4.5.1 Installation Warnings, Cautions and Recommendations Reminder
PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED
THIS STOVE USES A PRESSURIZED VENTING SYSTEM. ALL VENT CONNECTOR
JOINTS MUST BE SEALED AND FASTENED. CONSULT THE PELLET VENT
MANUFACTURER’S INSTRUCTION TO ENSURE PROPER INSTALLATION,
CONSISTENT PERFORMANCE, AND TO AVOID SMOKE AND ASH SPILLAGE.