8.3.6 N Code
THE STOVE FUNCTIONS BUT DISPLAYS WARNING CODE
Possible Cause:
Possible Remedy:
1.
A reversed polarity is detected on the
electrical outlet or on the same electrical
circuit.
Test and ensure the proper connections.
2.
No ground is detected or connected in the
wall outlet.
Test and ensure the proper connections of
the electrical wires and/or correct the grounds
of the unit.
8.3.7 C Code
THE STOVE FUNCTIONS BUT DISPLAYS WARNING CODE
Possibles Cause: Possible Remedy :
Warning generated by a power failure
while the stove was running.
The stove will restart on the initial setting once it
cools off.
Note: For a short power failure (less than 5
seconds), the stove will continue to function at the
selected speed.
8.3.8 I Code
STOVE FEEDS PELLETS, BUT WILL NOT IGNITE AND APPEARS ON THE
CONTROL BOARD
Possible Cause: Possible Remedy:
1. The igniter fuse on the control board
has blown.
Test the resistance (ohms, ) with a
multimeter. If the value is near zero, replace
the igniter and the F3 fuse.
2. The wiring harness shorted. Inspect the wiring and replace any defective
wire and or connector. Make sure the wires
are not shorted to the stove frame. Locate the
fuse F3 on the control board and replace it.
See Section 9.2: Testing a Component)
and follow instructions for component check.
Test the igniter to see if it glows. It should
take no longer than two minutes.