Product Manual
Eco-65 Installation and Operation Manual
60
to keep the exhaust temperature high
enough. To resolve the situation increase
feed rate or replace the part (see Section
5.2.2: Adjusting the Convection Fan
Speed).
8.3.5 d Code
STOVE STOPS FEEDING PELLETS AND APPEARS ON THE CONTROL BOARD
Possible Cause: Possible Remedy:
1. The hopper lid has stayed open for more
than 3 minutes.
As a security measure, the auger stops
turning and feeding pellets as soon as the
hopper lid opens. It will resume normal
operation as soon as the hopper lid is closed.
If the hopper lid stays open for more than 3
minutes, the stove will stop.
2. The hopper lid safety switch is faulty or
disconnected.
Make sure that the switch wiring is properly
connected. If it is, the hopper switch may be
faulty (see Section 8.2: Testing a
Component) and verify the proper function of
the safety switch. Replace it if necessary.