Product Manual
Eco-65 Installation and Operation Manual
54
8.3.2 H Code
STOVE STOPS FEEDING PELLETS AND APPEARS ON THE CONTROL BOARD.
BEFORE RESETTING TAKE CARE IN READING THE POSSIBLE CAUSES AND THEN
PRESS ON AND AT THE SAME TIME FOR 2 SECONDS.
Possible Cause: Possible Remedy:
1. Inadequate fuel is used.
Remove the burn pot, make sure that all
openings are clear and check that no ash has
filled the tube around the igniter. Refer to the
maintenance section. Also, make sure that
the recommended fuel is used (see Section
4.8.1: Proper Fuel).
2. The flue is not properly installed. Make sure the venting system meets the
criteria in the Section 4: Venting System as
well as the venting system manufacturer’s
instructions.
3. The flue is blocked or needs cleaning. One of the following components is
obstructed or blocked; air intake shutter,
combustion blower, burn pot, heat
exchangers and channels, exhaust blower
and or venting system. Refer to Section 7:
Maintenance.
4. The stove needs maintenance. Refer to Section 7: Maintenance.
5. The burn pot is not installed properly. Make sure the burn pot is installed correctly
(see Section 7.1.4: Cleaning the Burn Pot).
6. The baffle is not installed properly or holes
may be blocked.
Make sure the baffle is well installed and the
lock is in place. Make sure the holes are clear
(see Section 7.1.2: Cleaning the Baffle, the
Heat Exchanger and the Combustion
Chamber).
7. The convection blower is defective. See Section 8.2: Testing a Component and
test the convection blower.
8. he combustion blower needs cleaning. Carefully clean blower housing and make
sure blower louvers are not blocked.
9. The exhaust blower is defective. See Section 8.2: Testing a Component and
test the exhaust blower.