Operating instructions
Heatmax Furnace Installation and Operation Manual   
59 
9.2  Manual or thermostat control 
From factory, the opening and closing of the air inlet damper is manually activated by the 
means of a switch located at the rear of the furnace. The switch has two positions; opened 
and closed. 
For added comfort, the installation of an optional wall thermostat is recommended since it 
will open the air inlet damper when the room temperature is below the set point of the 
thermostat and will close the air inlet damper as the desired temperature is reached (see 
Appendix 1: Optional Thermostat Installation). 
If the heat sensors detect any overheating in the air jacket of the furnace, the air inlet 
damper will close automatically regardless of the type of control used. 
9.3 Fan control 
The fan is activated when the air jacket temperature of the furnace reaches 140 °F and 
stops when it drops below 120 °F. If the air jacket temperature exceeds 160 °F, the air inlet 
damper closes and the fan will continues to blow until temperature returns below 120 °F at 
which point the air inlet control will open again. 
To optimize the heat distribution efficiency of the furnace, the blower of the HEATMAX was 
set at the factory on speed 2 (medium-low). If needed, it is possible to change the fan 
speed by moving the black wire coming from the control box to the desired speed (see 
electrical diagram). Make sure the new setting complies with the recommendations of the 
National Association of Hot Air Heating and Air Conditioning while respecting the 
recommended static pressure. 