6 The exhaust system
WARNING
DO NOT INSTALL A MANUAL DAMPER IN THE EXHAUST PIPE ON THIS FURNACE.
CAUTION
BEFORE CONNECTING THE FURNACE TO THE EXHAUST SYSTEM, SURE THAT
THE EXHAUST PIPE AND/OR THE EXCHANGERS OF THE FURNACE ARE FREE OF
ALL ITEMS.
6.1 The chimney
The furnace must be connected to a factory-built metal chimney that complies with UL 103
HT (USA) or ULC S629 (Canada).
Recommended inner diameter: 6" (152 mm).
A chimney having a diameter of at most 7" (178 mm) is permitted, if it allows the proper
venting of combustion gases and that such application is verified and authorized by a
qualified installer. Otherwise, the diameter of the flue must be reduced to 6" (152 mm)
by the use of a stainless steel liner.
6.1.1 Factory-built metal chimneys
To be suitable, a factory-built metal chimney also
called “high temp” chimney, must comply with UL
103 HT (U.S.A.) or ULC S629 (Canada).
Use only components intended for the brand and
model of chimney you are using.
Never substitute parts from other chimney
brands.
Never fabricate your own components.
The chimney must be a type suitable for solid
fuel.
To be safe and effective, the chimney must be
installed exactly in accordance with the chimney
manufacturer’s instructions.