4.3 Non-authorized installation configuration
4.3.1 Non-authorized installation configuration in Canada and United States
The hot air distribution duct of the
furnace (A) must not be installed in the
air return duct of the furnace (B).
The hot air distribution duct (B) must not
be installed in the air return duct of the
furnace (A).
5 Positioning the unit and clearances to combustible
materials
To reduce the risk of vibration, the furnace must be leveled in both directions and
supported evenly to ensure stability.
5.1 Unit positioning
The furnace must be installed where outside air supply will be sufficient for proper
combustion. If required, a fresh air return adaptor kit (sold separatly) can be installed to
supply combustion air to the room or space.
The furnace must be positioned so that the flue pipe is as short as possible. Minimize the
use of 90° elbows.
The owner must ensure a proper installation to allow a safe operation of the appliance.
The owner must ensure cleanliness of the room in the event of negative pressure or
temporarily negative pressure.
5.2 Certification label
WARNING
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE
INSTRUCTIONS ON THE CERTIFICATION LABEL APPLIED ON THE UNIT.