Product Manual
Black Stag Installation and Operation Manual
38
8.2.2 Factory-built Metal Chimneys
in mobile homes
For use in a mobile home, this stove is
to be connected to a 6” in diameter
double wall factory built chimney
conforming to CAN/ULC-S629,
Standards for 650°C Factory-built
chimney and to UL 103 HT Standard
« Factory-Built Chimneys for Residential
Type and Building Heating
Appliances ». The total length of the flue
system should be at least 12 feet
including elbows, from the top of the
stove.
To maintain an effective vapour barrier,
insulation and waterproof at the chimney
and outside flue pipe, install a mobile
home roof flashing and seal it with
silicone.
8.2.3 Masonry Chimneys
The stove may also be connected to a
masonry chimney, provided the chimney
complies with the construction rules
found in the building code enforced
locally. The chimney must have either a
clay liner or a suitably listed stainless
steel liner. If the masonry chimney has a
square or rectangular liner that is larger
in cross sectional area than a round 6”
flue, it should be relined with a suitably
listed 6” stainless steel liner. Do not
downsize the flue to less than 6” unless
the venting system is straight and
exceeds 25 feet in height. When
passing through a combustible wall, the
use of an insulated listed thimble is
required.