Clearances for mobile homes
MOBILE HOME
APPLIANCE
CLEARANCES
(INSTALLATION WITH DOUBLE WALL PIPE
CONNECTOR)
CANADA USA
A
8" (203 mm) 8" (203 mm)
B
26" (660 mm) 26" (660 mm)
C
16" (406 mm) 16" (406 mm)
K
48" (1220 mm) 48" (1220 mm)
L
84" (213 cm) 84" (213 cm)
If the above clearances are met, then the distances measured from the flue outlet
will be:
DISTANCES* FROM PIPE CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA USA
D
11 1/2" (292 mm) 11 1/2" (292 mm)
E
35" (889 mm) 35" (889 mm)
F
24 1/2" (622 mm) 24 1/2" (622 mm)
*The pipe distances listed in this table refer to the distances obtained when Black
Stag is installed in accordance with the appliance clearances above mentioned.
However, you can install the Black Stag at reduced clearances; follow the
instructions in Section 7.4: Reducing Wall and Ceiling Clearances Safely. Where
they are followed, the new distance of the pipe to combustible materials must be
respected in the appropriate certification of the pipe.