Installation Guide

Installation and Operation Manual for Escape 1800
31
Clearances with ceiling (L) lowered to 76" (193 cm)
APPLIANCE CLEARANCES
(INSTALLATION WITH SINGLE
WALL PIPE CONNECTOR)
CANADA USA
A 15" (381 mm) 15" (381 mm)
B 17" (432 mm) 17" (432 mm)
C 14" (356 mm) 14" (356 mm)
K 48" (1220 mm) 48" (1220 mm)
L 76" (193 cm) 76" (193 cm)
APPLIANCE CLEARANCES
(INSTALLATION WITH DOUBLE
WALL PIPE CONNECTOR)
CANADA USA
A 8" (203 mm) 8" (203 mm)
B 17" (432 mm) 17" (432 mm)
C 9" (229 mm) 9" (229 mm)
K 48" (1220 mm) 48" (1220 mm)
L 76" (193 cm) 76" (193 cm)
If the above clearances are met, then the distances measured from the flue outlet
will be:
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA USA
D 18¾" (476 mm) 18¾" (476 mm)
E 27" (686 mm) 27" (686 mm)
F 25¼" (641 mm) 25¼" (641 mm)
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA USA
D 11¾" (298 mm) 11¾" (298 mm)
E 27" (686 mm) 27" (686 mm)
F 20¼" (514 mm) 20¼" (514 mm)
*The pipe distances listed in this table refer to the distances obtained when the
stove is installed in accordance with the appliance clearances above mentioned.
However, you can install the stove at reduced clearances; follow the instructions in
Section 7.4: Reducing Wall and Ceiling Clearances Safely. Where they are followed,
the new distance of the pipe to combustible materials must be respected in the
appropriate certification of the pipe.