Installation Guide

Columbia Installation and Operation Manual
30
Clearances for mobile homes
MOBILE HOME APPLIANCE CLEARANCES
(INSTALLATION WITH DOUBLE WALL PIPE
CONNECTOR)
CANADA USA
A 6" (152 mm) 6" (152 mm)
B 11" (279 mm) 11" (279 mm)
C 5" (127 mm) 5" (127 mm)
K 48" (1219 mm) 48" (1219 mm)
L 84" (213 cm) 84" (213 cm)
Important Note: Addition required to the stove when it is installed in a mobile home. See
Appendix 1: Installing the Optional Fresh Air Intake Kit (AC01338) for details.
If the above clearances are met, then the distances measured from the flue outlet
will be:
DISTANCES* FROM PIPE CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA USA
D 9¾" (248 mm) 9¾" (248 mm)
E 21" (533 mm) 21" (533 mm)
F 15" (381 mm) 15" (381 mm)
*The pipe distances listed in this table refer to the distances obtained when the
stove is installed in accordance with the appliance clearances above mentioned.
However, you can install the stove at reduced clearances; follow the instructions in
Section 7.4: Reducing Wall and Ceiling Clearances Safely. Where they are followed,
the new distance of the pipe to combustible materials must be respected in the
appropriate certification of the pipe.