Specifications
Installing the control panels
2.1.4
Power consumption
2
-8
2.1.4 Power consumption
The table below lists the power each YS 840DI system unit consumes. When designing a
control panel, use this data.
Function Name Power
consumption
(supply voltage)
Other units powered by this unit
Power supply module PS module 10
2.6A 270W
(200 VAC)
• Power supply backup module
(UPS module 10)
• Power supply backup battery
(UPS BATTERY)
• CNC unit (PCU50)
• Operation panel/NC keyboard
(OP010F □ )
Machine
control
panel
OP032S
6W
(24 VDC)
None
Machine
control
panel I/O
PP module
11W
(24 VDC)
None
I/O power supply
module
PS307(2A)
10W
(200 VAC)
• Interface module (ET200M)
• I/O module (SM321/322/323)
• Power supply for I/O loads
PS307(5A)
18W
(200 VAC)
PS307(10A)
30W
(200 VAC)
Converter CIMR-MRXN20455A
(
200 VAC
)
• Inverter
• Servo unit
CIMR-MRXN20375A
(
200 VAC
)
CIMR-MRXN20305A
(
200 VAC
)
CIMR-MRXN20225A
(200 VAC)
CIMR-MRXN20185A
(200 VAC)
CIMR-MRXN20155A
(200 VAC)
CIMR-MRXN20115A
(200 VAC)
CIMR-MRXN27P55A
(200 VAC)
CIMR-MRXN25P55A
(200 VAC)
CIMR-MRXN23P75A
(200 VAC)