Specifications

Installing the control panels
2.1.3
Heat dissipation
2
-6
2.1.3 Heat dissipation
The table below lists the heat each YS 840DI system unit dissipates.
Function Name
Heat dissipation
Total heat
dissipation
(W)
Heat
dissipation
inside panel
(W)
Heat dissipation
outside panel
(by heat sink)
(W)
Minimum
air flow rate
(m/s)
CNC unit PCU50
130
−−
Operation panel
OP010F
24
NC keyboard
Machine
control
panel
OP032S
Power supply module PS module 10
10.5
Power supply backup
module
UPS module
10
Power supply backup
battery
UPS BATTERY
1
Machine control panel
I/O
PP module
11
I/O power supply module PS307 (24 VDC/2A output)
10
PS307 (24 VDC/5A output)
18
PS307 (24 VDC/10A output)
30
Interface module ET200M
4.5
Digital input module
SM321 (DI32 × 24 VDC)
6.5
SM321 (DI16 × 24 VDC)
3.5
SM321 (DI16 × 24 VDC source)
3.5
SM321 (DI16 × 120 VAC)
4.1
SM321 (DI8 × 120/230 VAC)
4.9
Digital output module
SM322 (DO32 × 24 VDC/0.5A)
0.26
SM322 (DO16 × 24 VDC/0.5A)
0.19
SM322 (DO8 × 24 VDC/2A)
6.8
SM322 (DO16 × 120 VAC/1A)
9
SM322 (DO8 × 120/230 VAC/2A)
8.6
Digital I/O module
SM323 (DI16/DO16 × 24 VDC/0.5A)
6.5
SM323 (DI8/DO8 × 24 VDC/0.5A)
4.5
Relay output module
SM322 (DO16 × 120 VAC REL)
4.5
SM322 (DO8 × 120/23O VAC REL)
2.2
Converter* CIMR-MRXN20455A
470 190 280 2.5
CIMR-MRXN20375A
CIMR-MRXN20305A
CIMR-MRXN20225A
CIMR-MRXN20185A
CIMR-MRXN20155A
CIMR-MRXN20115A
CIMR-MRXN27P55A
CIMR-MRXN25P55A