Specifications
Installing the control panels
2.1.1
Environmental conditions for installing the control panels and other system components
2
-2
2.1 Designing the panels
2.1.1 Environmental conditions for installing the control panels and other
system components
The operating temperature requirements for the YS 840DI system components are as fol-
lows:
If the operating temperature requirements were not observed, the performance could not be guaran-
teed.
The environmental requirements for the control panels are as follows:
Table 2.1 Environmental requirements for the control panels and other system components
Function Name
Allowable operating temperature
range
CNC unit PCU50
5
-
45 ℃
CNC operation panel (face)
OP010F □
CNC operation panel (back)
Machine control panel OP032S
0 - 45
℃
(face), 0 - 55
℃
(back)
Power supply module PS module
0
-
60 ℃
Power supply backup module UPS module
Power supply backup battery UPS battery
5
-
40 ℃
Machine control panel I/O PP module
0
-
55 ℃
I/O power supply module PS307
0 - 60
℃
(horizontal mounting),
0 - 40
℃
(vertical mounting)
Interface module ET200M
I/O module I/O module
SERVOPACK SERVOPACK
0 - 55
℃
,
0 - 45
℃
(heat sink)
Reactor/winding changeover switch Reactor
0
-
60 ℃
Braking power supply unit BK unit
0
-
60 ℃
Items Requirements
Ambient
temperature *1
During storage or transportation
-20 to +60
℃
During operation
5-30
℃
*2
Humidity 10-90% RH (with no dew)
Vibration and
shock
4.9 and 73.5 m/s
2
respectively
Atmosphere Without excessive airborne dust, machining oil mist, or organic solvent vapor
Power supply
module, I/O power
supply module
100 - 230 VAC 50/60Hz
Power supply Input supply voltage: 100/200 VAC; Frequency: 50/60 Hz
Converter Main power supply
200-230 VAC +10/-15%, 50/60 Hz
±
5%, three-phase
Control power supply
200-230 VAC +10/-15%, 50/60 Hz
±
5%, single-phase
IMPORTANT
Environmental conditions