Specifications
Drive data list
B.4 List of Inverter monitor data
A
-28
B.4 List of Inverter monitor data
The following monitor data have been confirmed with a digital operator for drives
.
UN
number
Item Description Unit
Un001 Speed feedback
min
-1
Un002 Speed reference
min
-1
Un003 Reserved
Un004 Torque reference Short-time duration rated torque
%
Un005 Reserved
Un006 Inverter output current
A
Un007 Output frequency
Hz
Un008 Internal status of the sequence
[4]
[3]
[2]
[1] [0]
RUN2
RUN1 RUN JOG1 ACCDECDY
ACCDEC IRDY ACC
−
−
−
−
−
−
−
RUN2 /* At operation */
RUN1 /* Operation command */
RUN /* Operation command */
JOG1 /* JOG command */
ACCDECDY /* At acceleration/deceleration */
ACCDEC /* At acceleration/deceleration */
IRDY
/* Inverter ready */
ACC
/* At acceleration */
Un009 External input signals
[4] [3] [2] [1] [0]
RDY EMG FOR REV TLH
TLL SC
−
CHW PPI
ORT LGR MGR CAX
−
RDY
/* At operation preparation */
EMG
/* Emergency stop */
FOR
/* Forward rotation */
REV
/* Reverse rotation */
TLH
/* Torque limit H */
TLL
/* Torque limit L */
SC
/* Soft start cancelled */
CHW
/* Winding switch-over ON: Low-
speed winding*/
PPI
/* Speed controlling PP1 switch-over
ON: PI*/
ORT
/* Orientation */
LGR
/* L gear selection */
MGR
/* M gear selection */
CAX
/* C-axis switch-over */
Un010 External output signals
[4] [3] [2] [1] [0]
ZSPD AGR SDET TDET TLE
ORGSIG OREND CHWEND FLTSIG TALM
−
−
−
−
CAXCMP
ZSPD /* Zero speed */
AGR /* Speed matching */
SDET /* Speed detection */
TDET /* Torque detection */
TLE /* At torque limit */
ORGSIG /* Load-axis zero point */
OREND /* Orientation completed */
CHWEND /* Winding switch-over completed ON:
Low-speed winding*/
FLTSIG /* Failure */
TALM /* Error warning */
CAXCMP /* C-axis switch-over completed */
Un011 Inverter capacity
kW
Un012 Motor temperature
℃
Un013 Heat sink temperature
℃
Un014 Direct-current voltage of the bus
V