Specifications

Drive data list
A.3 List of Inverter parameter
A
-14
6132 Cn132
25 0 500
msec Hunting Time Antihunting time constant
6133 Cn133
10 0 100
% Hunting Limit Antihunting limit
6150 Cn150
1900 0 4600
v Voltage Cntrl Volt Voltage limiting control setting
voltage
6151 Cn151
100 0 10000
0.01 Voltage Cntrl P Gain Voltage limiting control proportional
gain
6152 Cn152
40 0 5000
sec Voltage Cntrl I Time Voltage limiting control integration
time
6153 Cn153
20 0 5000
sec Voltage Cntrl Fil Time Voltage limiting control output filter
time constant
6154 Cn154
10 0 5000
sec D Axis Torque Filter d-axis current torque filter time
constant
6155 Cn155
001
None Voltage Cntrl Sel Voltage limiting control selection
6156 Cn156
001
None Max Torque Sel Max. torque coefficient control
selection
6200 Cn200
15 10 100
% Motor Flux Lower Limit Motor flux lower limit level
6201 Cn201
100 30 100
% Sv Mode Flux Level H Servo mode flux level (H)
6202 Cn202
100 100 500
0.01 Sv Base Speed Ratio H Servo mode base speed ratio (H)
6203 Cn203
100 30 100
% Sv Mode Flux Level M L Servo mode flux level (ML)
6204 Cn204
100 100 500
0.01 Sv Base Speed Ratio M L Servo mode base speed ratio (ML)
6259 Cn259
001
None Load Ratio Output Ref Load ratio meter output reference
selection
6263 Cn263
003
None Load Ratio Meter Filter Load ratio meter filter time constant
6400 Cn400
15 10 50
% Speed-agree Width Speed matching signal
6401 Cn401
1000 0 10000
0.01% Speed Detection Level Speed detection signal level
6402 Cn402
100 0 10000
0.01% Speed Detection Width Speed detection signal hysteresis
6403 Cn403
001
None Excessive Speed Dev Sens Dynamic sensitivity selection of
excessive speed deviation
6404 Cn404
003
None Excessive Speed Dev Time Delay time selection of excessive
speed deviation protection
6405 Cn405
001
None Speed Agree Signal Sel AGR output condition selection
6410 Cn410
100 50 2000
0.1% Torqu Detection Level Torque detection signal level
6411 Cn411
10 0 100
0.1% Torqu Detection Width Torque detection signal hysteresis
6412 Cn412
001
None Torque Detection Output TDET output method at acceleration
6420 Cn420
10 0 210
% Ext Torque Limit External steering torque limiting
level
6421 Cn421
150 0 210
% Torque Limit Torque limiting level at electric
operation side
6422 Cn422
150 0 210
% Regeneration Torque Limit Torque limiting level at regeneration
side
6423 Cn423
001
None Torqu Limit Select Torque limiting selection
6450 Cn450
190 150 210
v Undervoltage Detect Level Low voltage detection level
6472 Cn472
00799
None Monitor 1 Output Monitor 1 output description
6475 Cn475
10799
None Monitor 2 Output Monitor 2 output description
6495 Cn495
0xB 0x0000 0x002F
Hex Inverter Capacity Sel Inverter capacity selection
6500 Cn500
7000 100 60000
min
-1
Rated Speed Setting Rated speed setting
6504 Cn504
001
None Torqu Limit Auto Judge Torque limit auto detect selection
CNC
paramete
r number
Drive
parameter
number
Initial
value
Lower
limit
Upper
limit
Unit Display name Description