Specifications

12.2
Application
12
-27
Analog monitor output manual gain adjustment
Use the following procedure for manual gain adjustment for analog monitor output.
1. On the axis selection mode, select the axis you want to operate.
2. Press the [DSPL/SET] key and select the auxiliary function execution mode.
3. Select the user constant Fn00D. Press the [LEFT] or [RIGHT] key to select the setting
digit. Press the [UP] or [DOWN] key until the value you want to set is displayed.
4. Press the [DATA/ENTER] key. The indication will display like below.
5. Press the [DSPL/SET] key to switch over the 2-channel monitor output.
6. Press the [LEFT] or [RIGHT] key to view the analog monitor gain factor. Press the
[LEFT] or [RIGHT] key again to return to the display of Step 4 or Step 5.
7. Press the [UP] or [DOWN] key to enable the analog monitor output gain adjustment.
8. After the gain adjustment for the two output channels, press the [DATA/ENTER] key.
The indication will return to the auxiliary function execution mode display.
This completes the analog monitor output manual gain adjustment.
[DSPL/SET] key
Changes alternately.
Data display
Changes alternately
[LEFT] key
([RIGHT] key)
Data setting changed.