Specifications

12.2
Application
12
-25
When the servo drive is powered on, pressing the [DSPL/SET] or [MODE/SET] key can not initialize
the user constant.
After initializing the user constant, you must turn off and then turn on the power supply.
12.2.7 Manual zero adjustment and gain adjustment for analogue monitor
output
This analog monitor output can allows you to observe the motor speed, torque reference or
position deviation. For the detailed information, see the section 16.4 "Analog Monitor".
The analog monitor output manual zero adjustment function is used for compensating the
output voltage deviation which is caused by drift, or the zero point deviation which is caused
by noise interference with observation system. Also, the gain adjustment function can be
modified to meet the sensitivity of observation system.
The output voltage range of analog monitor is ± 8V (MAX). Even if the voltage exceeds this range,
the indication shows only ± 8V.
INFO
Monitor output voltage
Zero adjustment
Gain
adjustment
Zero adjustment range
:±
2V
→ 
24mV/LSB
Gain adjustment range
50 to 150
% → 
0.4
/LSB
Setting unit
INFO