Specifications

12.2
Application
12
-21
6. Press the [DSPL/SET] key to view the encoder type and resolution identification data.
7. DSPL/SET key to view the special specification number of SERVOPACK (Y specifica-
tion number).
8. Press the [DATA/ENTER] key to return to the auxiliary function mode. You can also
return to the auxiliary function mode by pressing the [DATA/ENTER] key after viewing
the indication of Step 4 to Step 6.
This completes checking the motor type.
Encoder resolution
Encoder type Data Resolution
Data Type 13 13 bits
00 Incremental encoder 16 16 bits
01 Absolute value encoder 17 17 bits
20 20 bits
The example on the left shows the special
specification "Y10".
(Displayed with decimal number)
Encoder type
Encoder resolution