Specifications

12.2
Application
12
-19
12.2.2 Clearing the alarm trace back data
This function allows to clear the alarm history stored in the SERVOPACK. When the func-
tion is enabled, all the alarm generation history is set "A. - -" which does not mean an alarm.
For the details, see the section 12.2.1 "Operation on the alarm trace back mode".
To clear the alarm trace back data, use the following procedure.
1. On the axis selection mode, select the axis you want to operate.
2. Press the [DSPL/SET] key and select the auxiliary function execution mode.
3. Select the user constant Fn006.
Press the [LEFT] or [RIGHT] key to select the setting digit.
Press the [UP] or [DOWN] key until the value you want to set is displayed.
4. Press the [DATA/ENTER] key. The screen is displayed as below.
5. Press the [DSPL/SET] key. The following display flashes a second, the alarm trace back
data is cleared and then the screen displays the indication as Step 4.
6. Press the [DATA/ENTER] key to return to the user constant number display.
This completes clearing the alarm trace back data.
flashes a seconds